E93.1801EN171 HWB installation manual
56
Concentric sidewall multiple water heaters termination.
NOTE: keep the terminals horizontally in the same line and at min. 12” above grade or snow line.
Roof (Vertical) direct venting.
10.12.1
V
ENT
/
AIR TERMINATION
–
VERTICAL
Follow instructions below when determining vent location to avoid possibility of severe per-
sonal injury, death or substantial property damage.
10.12.2
D
ETERMINE LOCATION
Locate the vent/air terminations using the following guidelines:
1. The total length of piping for vent or air must not exceed the limits given in the section 9.1 on page 34 of this
manual.
2. Prepare the vent termination and the air intake termination elbow (figure below) by inserting bird screens.
3. The exhaust vent must terminate at least 3 feet above the highest place in which the exhaust vent penetrates
the roof and at least 2 feet above any part of a building within 10 horizontal feet.
4. The air intake piping must terminate in a down-turned 180° direction utilizing two elbows see figure below
5. The exhaust piping must terminate in a vertical coupling as shown in figure below. The top of the coupling
must be at least 1 foot above the air intake. When the vent termination uses a rain cap, maintain at least 36"
(914 mm) above the air inlet. The air intake pipe and exhaust vent pipe can be located in any desired position
on the roof, provided that the exhaust vent termination is at least 1 foot above the air intake.
6. Maintain the required dimensions of the finished termination piping as shown in figure below.
7. Do not extend exposed vent pipe outside of building more than shown in this document. Condensate could
freeze and block vent pipe.
Rooftop exhaust vent and air intake inlet terminations must terminate in the same pressure
zone.
WARNING
WARNING
Summary of Contents for HWB-299
Page 2: ......
Page 7: ...E93 1801EN171 HWB installation manual 7 1 SAFETY GUIDELINES...
Page 8: ...E93 1801EN171 HWB installation manual 8 CONSIGNES DE S CURIT...
Page 65: ...E93 1801EN171 HWB installation manual 65 Ladder Logic Diagram...
Page 66: ...E93 1801EN171 HWB installation manual 66 Electrical schematics...
Page 67: ...E93 1801EN171 HWB installation manual 67...
Page 119: ...E93 1801EN171 HWB installation manual 119 22 SPARE PARTS...
Page 120: ...E93 1801EN171 HWB installation manual 120 68 68 73...
Page 123: ......