EBS-6100
Printer User's Manual
Paragraph 4 - Operating the Printer
EBS
Ink-Jet Systems
®
46
20070529#20.5
Create a subfile in the form of a special register (
a universal counter
) within the text file
to be printed onto packages. Type in the following text:
000/000
. Set the following
universal counter parameters:
Print beg.
=
CONTINUE
,
Mode
=
Standard
,
Beg.value1
=1,
Min.value1
=1,
Max.value1
=4,
Cnt.delta1
=1,
Beg.value2
=1,
Min.value2
=1,
Max.value2
=20,
Cnt.delta2
=1,
Cnt.value2
=1,
0 suppress
=
NO
The following labels are printed on packages if the above settings have been set:
001/001, 001/002, ... , 001/020, 002/001, 002/002, ... , 002/020, 003/001, ...... , 004/019,
004/020, 001/001, etc.
NOTE:
If the numbering of packages has been interrupted for some reason during the
printing, you can stop the printing, reset the
Print beg.
parameter to
BEG.VALUE,
set both counters to the initial settings with the
Beg.value1
and
Beg.value2
parameters and resume the printing.
000/ 000
000/ 000
000/ 000
001/ 001
000/ 000
000/ 000
000/ 000
001/ 005
000/ 000
000/ 000
000/ 000
001/ 009
000/ 000
000/ 000
000/ 000
001/ 013
000/ 020
000/ 019
000/ 018
001/ 017
000/ 000
000/ 000
000/ 000
002/ 001
000/ 000
000/ 000
000/ 000
002/ 005
000/ 000
000/ 000
000/ 000
002/ 009
000/ 000
000/ 000
000/ 000
002/ 013
000/ 020
000/ 019
000/ 018
002/ 017
000/ 000
000/ 000
000/ 000
003/ 001
000/ 000
000/ 000
000/ 000
003/ 005
000/ 000
000/ 000
000/ 000
003/ 009
000/ 000
000/ 000
000/ 000
003/ 013
000/ 020
000/ 019
000/ 018
003/ 017
000/ 000
000/ 000
000/ 000
004/ 001
000/ 000
000/ 000
000/ 000
004/ 005
000/ 000
000/ 000
000/ 000
004/ 009
000/ 000
000/ 000
000/ 000
004/ 013
000/ 020
000/ 019
000/ 018
004/ 017
000/ 000
000/ 000
000/ 000
001/ 001
000/ 000
000/ 000
000/ 000
001/ 005
000/ 000
000/ 000
000/ 000
001/ 009
000/ 000
000/ 000
000/ 000
001/ 013
000/ 020
000/ 019
000/ 018
001/ 017
Direction in
which pallets
are placed
Order A, B and direction in which
packages are stored on pallets
1st pallet
4th pallet
3rd pallet
2nd pallet
1st pallet
2nd shelving
1st shelving
1 2 3 4 5
C
A
B
1
2
3
4
Fig. 4.4.1.10.1.
The operation of the universal counter in Example 1
2).
Universal counter with
Mode
=
Special
.
Additional parameters of the universal counter are available in this mode. They are:
Spc.Md.max
,
Spc.Md.cnt
and
Pal.countr
- see the table above. With them, the
numbering of products can be automated and fit subsequent packing and storing on
pallets or shelves in a hierarchical way. In this mode the other parameters are similar
to those used in the
Standard
mode except for the
Beg.value1
and
Beg.value2
parameters. These two parameters are not available and therefore cannot be used to
set both counters of the universal counter to their initial settings. In the
Special
mode,
the initial settings need to be introduced by editing the universal-counter subfile
directly (and inputting 2 groups of digits and a separator).
EXAMPLE 2:
Creating a special counter to allow for peculiarity of product packing in a company
Assumptions
: Small unit packages (products) moving sequentially on a factory conveyor
are packed in fours into type
I
packages, then the type
I
packages are put in groups of 64
into boxes (type
II
packages). The type
II
packages are stored on pallets in one layer, with
4*5=20 packages in the layer. The packages are arranged on the pallet in
A
,
B
order and
Summary of Contents for EBS-6100
Page 1: ...EBS Ink Jet Systems EBS 6100 USER S MANUAL...
Page 2: ......