IF 1946 • 09/22                                                         Copyright © 2022, Eaton’s Crouse-Hinds Division                                                                   Page 2

INSTALLATION

A. M2-FLUSH-MT-KIT

1.  Make sure the power is disconnected to the conduit system before 

installing the luminaire.

2.  Install flush mount brackets to rear of luminaire driver housing using 

the provided two (2) 1/4” hex bolts and split ring lock washers for each 

bracket. Bracket orientation as shown in Figure 1. Torque to 64 in.-lbs (7.2 

N-m)

3.  Identify mounting location suitable for supporting luminaire, mark and drill 

holes for flush brackets per dimensions shown in Figure 1.

4.  Luminaire is now ready for mounting. It is strongly suggested to use 

two (2) qualified tradespeople to proceed with the final mounting of the 

luminaire. This is recommended to avoid any personal injury or damage to 

the luminaire.

5.  Install and tighten four (4) 1/4” diameter fasteners (customer supplied) in 

bracket mounting holes. It is recommended that stainless steel hardware 

be used in locations with corrosion concerns.

Figure 1. Flush Ceiling Mount Installation

!

WARNING

To avoid injury to personnel,

 do not let the luminaire hang or flex on one 

bracket at a time.  Failing to comply will result in breakage of bracket and 

possible injury or death.  

Length

2 Foot 

(in)

2 Foot 

(mm)

4 Foot 

(in)

4 Foot 

(mm)

A

24.0

610

39.0

991

B

24.25

616

24.25

616

C

2.50

63.5

2.50

63.5

THIRD ANGLE PROJECTION

B

C

A

660

26.0

A

123.2

4.85

175.3

6.90

1/4-20 x 1/2" HEX HEAD BOLT

1/2" SPLIT LOCK WASHER

ZONE NO.

DESCRIPTION

DATE

APPRD.

LTR. NO.

CCHSY-SW-Template-D

SW_REV   11/2015

DO NOT SCALE DRAWING

NOTES:
1. 

A

B

C

D

1

2

3

4

5

6

7

8

A

D

C

B

8

7

6

5

4

3

2

1

Your name

ASSY2

CAT2
CAT1

ASSY1

ARE IN

MILLIMETERS.

DIMENSIONS IN [ ] ARE IN

ALL PRIMARY DIMENSIONS

UNLESS OTHERWISE SPECIFIED,

MM/DD/YYYY

Your Name

WITH ASME Y14.5 2009.

DIM AND TOL IN ACCORDANCE

±

±

±

±

.1

.3

INCHES.

rev

0000000

WT.   15.84 LB

SCALE   1:2

FIRST MADE FOR   Catalog Family

Title Line 1

APPROVED BY

DRAWN BY

Finish

... THICK

Material

mm

in.

.13
.000
1.5

Your Name

THIS IS PROPERTY OF EATON AND CONTAINS CONFIDENTIAL AND

TRADE SECRET INFORMATION.  POSSESSION DOES NOT CONVEY

ANY RIGHTS TO LOAN, SELL OR DISCLOSE SAID INFORMATION.

REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN WHICH

IT WAS SUPPLIED MAY NOT BE MADE WITHOUT EXPRESS

WRITTEN PERMISSION OF EATON.  THIS DRAWING IS ON LOAN

AND IS TO BE RETURNED UPON REQUEST.

        

Title Line 2

     

Your Name

MM/DD/YYYY

1.5

±

.005

±

.01

±

±

ANGLES

.XXX

.XX

.X

REDRAWN DATE

ORIGINAL DATE

UNLESS OTHERWISE SPECIFIED

TOLERANCES

MATERIAL:

FINISH:

APPROVED BY

CHECKED BY

USED ON

APPLICATION

NEXT ASSY.

TITLE

CODE IDENT. NO.

SIZE

REV.

D

SHEET   1  OF  5

     

CODE ...

THIRD ANGLE PROJECTION

B

C

A

660

26.0

A

123.2

4.85

175.3

6.90

1/4-20 x 1/2" HEX HEAD BOLT

1/2" SPLIT LOCK WASHER

ZONE NO.

DESCRIPTION

DATE

APPRD.

LTR. NO.

CCHSY-SW-Template-D

SW_REV   11/2015

DO NOT SCALE DRAWING

NOTES:
1. 

A

B

C

D

1

2

3

4

5

6

7

8

A

D

C

B

8

7

6

5

4

3

2

1

Your name

ASSY2

CAT2
CAT1

ASSY1

ARE IN

MILLIMETERS.

DIMENSIONS IN [ ] ARE IN

ALL PRIMARY DIMENSIONS

UNLESS OTHERWISE SPECIFIED,

MM/DD/YYYY

Your Name

WITH ASME Y14.5 2009.

DIM AND TOL IN ACCORDANCE

±

±

±

±

.1

.3

INCHES.

rev

0000000

WT.   15.84 LB

SCALE   1:2

FIRST MADE FOR   Catalog Family

Title Line 1

APPROVED BY

DRAWN BY

Finish

... THICK

Material

mm

in.

.13
.000
1.5

Your Name

THIS IS PROPERTY OF EATON AND CONTAINS CONFIDENTIAL AND

TRADE SECRET INFORMATION.  POSSESSION DOES NOT CONVEY

ANY RIGHTS TO LOAN, SELL OR DISCLOSE SAID INFORMATION.

REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN WHICH

IT WAS SUPPLIED MAY NOT BE MADE WITHOUT EXPRESS

WRITTEN PERMISSION OF EATON.  THIS DRAWING IS ON LOAN

AND IS TO BE RETURNED UPON REQUEST.

        

Title Line 2

     

Your Name

MM/DD/YYYY

1.5

±

.005

±

.01

±

±

ANGLES

.XXX

.XX

.X

REDRAWN DATE

ORIGINAL DATE

UNLESS OTHERWISE SPECIFIED

TOLERANCES

MATERIAL:

FINISH:

APPROVED BY

CHECKED BY

USED ON

APPLICATION

NEXT ASSY.

TITLE

CODE IDENT. NO.

SIZE

REV.

D

SHEET   1  OF  5

     

CODE ...

INSTALLATION

Max. mounting height of 

25.2 ft (7.68m)

B. M2-CEILING-WALL-KT

1.  Make sure the power is disconnected to the conduit system before 

installing the luminaire.

2.  Mark and drill holes for fastening end brackets. Use two (2) 1/4” diameter 

fasteners (customer supplied) at center to center measurements (see 

Figure 2). It is recommended that stainless steel hardware be used in 

locations with corrosion concerns.

3.  Luminaire is now ready for mounting. It is strongly suggested to use 

two (2) qualified tradespeople to proceed with the final mounting of the 

luminaire. This is recommended to avoid any personal injury or damage to 

the luminaire.

4.  For end mount wall/ceiling mounting brackets, it is recommended to 

mount one bracket first and then, while supporting the luminaire, insert it 

into the mounted bracket, then attach the other bracket.

5.  Aim the luminaire to achieve desired light output and tighten the 1/4” set 

screws on brackets. Torque to 64 in.-lbs. (7.2 N-m).

6.  Use set screw to limit rotation of the luminaire.

Figure 2. Ceiling-Wall Mount Installation

Length

2 Foot 

(in)

2 Foot 

(mm)

4 Foot 

(in)

4 Foot 

(mm)

A

28.5

724

28.5

724

B

24.0

610

39.0

991

!

WARNING

To avoid injury to personnel,

 do not let the luminaire hang or flex on one 

bracket at a time.  Failing to comply will result in breakage of bracket and 

possible injury or death.  

THIRD ANGLE PROJECTION

A

B

175.3

6.90

205.2

8.08

63.5

2.50

54

2.13

B

723

28.5

CCHSY-SW-Template-D

SW_REV   11/2015

DO NOT SCALE DRAWING

NOTES:
1. 

A

B

C

D

1

2

3

4

5

6

7

8

A

D

C

B

8

7

6

5

4

3

2

1

Your name

ASSY2

CAT2
CAT1

ASSY1

ARE IN

MILLIMETERS.

DIMENSIONS IN [ ] ARE IN

ALL PRIMARY DIMENSIONS

UNLESS OTHERWISE SPECIFIED,

MM/DD/YYYY

Your Name

WITH ASME Y14.5 2009.

DIM AND TOL IN ACCORDANCE

±

±

±

±

.1

.3

INCHES.

rev

0000000

WT.   15.84 LB

SCALE   1:2

FIRST MADE FOR   Catalog Family

Title Line 1

APPROVED BY

DRAWN BY

Finish

... THICK

Material

mm

in.

.13

.000
1.5

Your Name

THIS IS PROPERTY OF EATON AND CONTAINS CONFIDENTIAL AND

TRADE SECRET INFORMATION.  POSSESSION DOES NOT CONVEY

ANY RIGHTS TO LOAN, SELL OR DISCLOSE SAID INFORMATION.

REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN WHICH

IT WAS SUPPLIED MAY NOT BE MADE WITHOUT EXPRESS

WRITTEN PERMISSION OF EATON.  THIS DRAWING IS ON LOAN

AND IS TO BE RETURNED UPON REQUEST.

        

Title Line 2

     

Your Name

MM/DD/YYYY

1.5

±

.005

±

.01

±

±

ANGLES

.XXX

.XX

.X

REDRAWN DATE

ORIGINAL DATE

UNLESS OTHERWISE SPECIFIED

TOLERANCES

MATERIAL:

FINISH:

APPROVED BY

CHECKED BY

USED ON

APPLICATION

NEXT ASSY.

TITLE

CODE IDENT. NO.

SIZE

REV.

D

SHEET   2  OF  5

     

CODE ...

Summary of Contents for Champ MLLA M2 Series

Page 1: ...6 Do not use this equipment for other than intended use 7 Replace entire battery unit and LED driver when necessary Contact the manufacturer for information on service 8 Do not attempt to service bat...

Page 2: ...ASSY2 CAT2 CAT1 ASSY1 ARE IN MILLIMETERS DIMENSIONS IN ARE IN ALL PRIMARY DIMENSIONS UNLESS OTHERWISE SPECIFIED MM DD YYYY Your Name WITH ASME Y14 5 2009 DIM AND TOL IN ACCORDANCE 1 3 INCHES rev 0000...

Page 3: ...AND TRADE SECRET INFORMATION POSSESSION DOES NOT CONVEY ANY RIGHTS TO LOAN SELL OR DISCLOSE SAID INFORMATION REPRODUCTION OR USE FOR ANY PURPOSE OTHER THAN WHICH IT WAS SUPPLIED MAY NOT BE MADE WITHOU...

Page 4: ...d of the support cable to one of the four 4 attachment points provided on the luminaire driver housing and secure the other end to a fixed support Use a minimum of two 2 support cables per luminaire s...

Page 5: ...ed conduit is torqued to 42 52 ft lbs 57 71 N m for 3 4 plug 4 Verify supply wires are connected to luminaire wire leads per Figure 14A Figure 14B or Figure 14C 5 Verify all electrical connections are...

Page 6: ...Figure 14A 2 Foot UNV1 Standard Wiring Diagram Figure 14B 4 Foot UNV1 Standard Wiring Diagram WIRING DIAGRAMS IF 1946 09 22 Copyright 2022 Eaton s Crouse Hinds Division Page 6...

Page 7: ...eck to make sure that all connections are clean and tight 7 Mechanically check that all parts are properly assembled 8 Check and re torque all mounting hardware 9 To prevent heat build up remove dust...

Page 8: ...sea necesario Comun quese con el fabricante para recibir informaci n acerca del servicio 8 No intente realizar el mantenimiento de la bater a 9 Consulte la etiqueta del producto para conocer la especi...

Page 9: ...T2 CAT1 ASSY1 ARE IN MILLIMETERS DIMENSIONS IN ARE IN ALL PRIMARY DIMENSIONS UNLESS OTHERWISE SPECIFIED MM DD YYYY Your Name WITH ASME Y14 5 2009 DIM AND TOL IN ACCORDANCE 1 3 INCHES rev 0000000 WT 15...

Page 10: ...ICH IT WAS SUPPLIED MAY NOT BE MADE WITHOUT EXPRESS WRITTEN PERMISSION OF EATON THIS DRAWING IS ON LOAN AND IS TO BE RETURNED UPON REQUEST Title Line 2 Your Name MM DD YYYY 1 5 005 01 ANGLES XXX XX X...

Page 11: ...ta del controlador de la luminaria Coloque los cables de soporte secundarios de modo que se limite la distancia vertical suspendida a no m s de 18 pulgadas desde la posici n de montaje primaria Se deb...

Page 12: ...recomienda aplicar aproximadamente 1 8 in de gotas de lubricante para roscas STL de Eaton en las entradas de conducto 3 Verifique que el conducto instalado est apretado con un torque de 42 52 ft lb 57...

Page 13: ...DE PLACA DE CIRCUITO IMPRESO DE LED CONTRO LADOR L NEA NEUTRO A TIERRA L NEA NEUTRO A TIERRA CONECTOR DE LUMINARIA WAGO CN2 L NEA NEUTRO A TIERRA LED LED TENUE TENUE INDICADOR DE CARGA MONTAJE REMOTO...

Page 14: ...cubierta LED con un cepillo suave o presi n de aire 10 Inspeccione visualmente la luz indicadora de estado de carga una vez al mes Debe estar encendida cuando la alimentaci n de CA est activa Si el in...

Page 15: ...mble de la batterie et du circuit de commande de DEL si n cessaire Communiquer avec le fabricant pour obtenir des renseignements sur le service 8 Ne pas essayer de faire un entretien de la batterie 9...

Page 16: ...T1 ASSY1 ARE IN MILLIMETERS DIMENSIONS IN ARE IN ALL PRIMARY DIMENSIONS UNLESS OTHERWISE SPECIFIED MM DD YYYY Your Name WITH ASME Y14 5 2009 DIM AND TOL IN ACCORDANCE 1 3 INCHES rev 0000000 WT 15 84 L...

Page 17: ...ANY PURPOSE OTHER THAN WHICH IT WAS SUPPLIED MAY NOT BE MADE WITHOUT EXPRESS WRITTEN PERMISSION OF EATON THIS DRAWING IS ON LOAN AND IS TO BE RETURNED UPON REQUEST Title Line 2 Your Name MM DD YYYY 1...

Page 18: ...bles de support par luminaire en fixant un seul c ble deux 2 emplacements sur l ext rieur du bo tier du pilote du luminaire Disposer les c bles de support secondaire de fa on limiter la distance vert...

Page 19: ...lets STL d Eaton d environ 1 8 po sur les orifices d entr e de conduit 3 V rifier que le conduit install est serr un couple de 42 52 pi lb 57 71 N m pour un bouchon de 3 4 po 4 V rifier que les fils d...

Page 20: ...CCI DE DEL LIGNE NEUTRE MISE LA TERRE LIGNE NEUTRE MISE LA TERRE CONNECTEUR POUR LUMINAIRES WAGO CN2 LIGNE NEUTRE MISE LA TERRE DEL DEL GRADATEUR GRADATEUR VOYANT DE CHARGE MONT DISTANCE FOURNI PAR LE...

Page 21: ...comprim 10 Inspecter visuellement le t moin d tat charge une fois par mois Il devrait tre allum lorsqu aliment en c a Si le voyant clignote communiquer avec le soutien technique 11 Tester le fonctionn...