background image

Operation Manual 

 
English 

 
 

 

 

cuvetteMIXdrive 1   

 

     

 

Order no.: 40400 

MIXdrive 1 XS   

 

 

    

 

Order no.: 40300 

MIXdrive 1 eco  

 

 

    

 

Order no.: 40101 

MIXdrive 1 

 

 

 

    

 

Order no.: 40001 

MIXdrive 6 

 

 

 

    

 

Order no.: 40006 

MIXdrive 15 

 

 

 

   

 

Order no.: 40015 

MIXdrive 60 

 

 

 

   

 

Order no.: 40060 

MIXdrive OEM   

 

 

    

 

Order no.: 4xxxx 

 

MIXdrive 1 XS HT 

 

 

     

 

Order no.: 40303 

MIXdrive 1 eco HT   

 

    

 

Order no.: 40301 

MIXdrive 1 HT   

 

 

     

 

Order no.: 40201 

MIXdrive 6 HT   

 

 

     

 

Order no.: 40206 

MIXdrive 15 HT  

 

 

     

 

Order no.: 40215 

MIXdrive 60 HT  

 

 

     

 

Order no.: 40260 

MIXdrive OEM HT 

 

 

    

 

Order no.: 4xxxx 

with 

MIXcontrol eco  

 

 

 

 

Order no.: 90100 

MIXcontrol eco DINrail (0-10V)     

 

Order no.: 90150 

MIXcontrol eco DINrail (Poti)           

Order no.: 90140 

MIXcontrol 20   

 

 

 

     

Order no.: 90200 

MIXcontrol 20 RS232 

 

 

 

Order no.: 90210 

MIXcontrol 20 DINrail (0-10V)   

     

Order no.: 90220 

MIXcontrol 20 DINrail (RS232)  

     

Order no.: 90221 

MIXcontrol 40   

 

 

 

     

Order no.: 90400 

MIXcontrol 40 RS232 

 

 

 

Order no.: 90410 

MIXcontrol 40 DINrail (0-10V)   

     

Order no.: 90420 

MIXcontrol 40 DINrail (RS232)  

     

Order no.: 90421 

 
Version 5.1  

 

       Issue 10/2015 

 

 

   

www.2mag.de

 

Summary of Contents for MIXdrive 1 XS

Page 1: ...er no 40206 MIXdrive 15 HT Order no 40215 MIXdrive 60 HT Order no 40260 MIXdrive OEM HT Order no 4xxxx with MIXcontrol eco Order no 90100 MIXcontrol eco DINrail 0 10V Order no 90150 MIXcontrol eco DIN...

Page 2: ...2mag AG Page 2 of 44 Version 5 1 Includes Quick start Operation Manual Technical Documentation Specifications...

Page 3: ...lling In these fields we are offering support with our products to the modern laboratory within the standardized daily business as well as for the implementation of highly complex processes in the sta...

Page 4: ...IXcontrol 20 40 ____________________ 17 4 2 1 Description operating elements MIXcontrol 20 40 _______________ 17 4 2 2 Stirring operation and stirrer control MIXcontrol 20 40 ___________ 18 4 3 Interf...

Page 5: ...dern inductive magnetic stirring system MIXdrive consisting of a stainless steel stirring plate with 1 6 15 or 60 stirring points with fixed stirrer control cable 4 pin plug with screw nut An external...

Page 6: ...r and 95 C in water immersed 2 3 Product combinations In addition to the use at the conventional laboratory desk our products have also been tested for the application in Laminar flow devices Safety c...

Page 7: ...asks that have a comparatively small diameter and thin bottom The magnetic stirring bar can then be centred better Magnetic Stirrer Stirring vessels Nominal content Max amount cuvetteMIXdrive 1 cuvett...

Page 8: ...Bars We recommend using 2mag ASTEROID stirring bars to increase the stirring performance at enhanced requirements ASTEROID stirring bars a newly developed high effective and ideal for large mixing vol...

Page 9: ...er magnetic stirring bar or Decrease the stirring power In case the magnetic stirring bar will not be centred or leaves the centre permanently The interaction between the alternating magnetic field an...

Page 10: ...osive rooms The control unit MIXcontrol must not be dipped in water or any cleaning solutions Your supply voltage has to comply with the label of the control unit The control unit has to be switched o...

Page 11: ...ve has now to be connected to the 4 pin socket of the control unit 7 Please secure this plug connection by turning the screw nut situated at the plug Only by this a trouble free operation can be guara...

Page 12: ...w voltage connector of the stirrer control cable 4 Low voltage socket for the stirrer control cable 5 Control unit MIXcontrol eco 6 Speed control rpm 7 Socket for control cable for the magnetic stirre...

Page 13: ...is plug connection by turning the screw nut situated at the plug Only by this a trouble free operation can be guaranteed Connect the power cable 4 to the power input 3 rear side and afterwards to the...

Page 14: ...t situated at the plug Only by this a trouble free operation can be guaranteed It can be connected directly up to two stirring drives MIXdrive of the identical type Connect the power cable 4 to the po...

Page 15: ...g of the control units 4 1 Operating of the control unit MIXcontrol eco Image 6 Functional elements control unit MIXcontrol eco 4 1 1 Description functional elements MIXcontrol eco 5 Control unit 2mag...

Page 16: ...netic stirrer will be turned off SoftStart After the magnetic stirrer was switched on the stirring bars in the flasks will first be caught afterwards centred in the flask and then to increase the oper...

Page 17: ...rol 20 40 4 2 1 Description operating elements MIXcontrol 20 40 7 Control unit 2mag MIXcontrol 20 40 Stirrer control 8 ON OFF key for magnetic stirrer 9 MODE key M for power adjustment of the magnetic...

Page 18: ...elerating phase will be shown by the illumination of a dot at the right segment of the LED display 10 Power adjustment A newly developed and extremely efficient magnetic stirrer will come into operati...

Page 19: ...d Press the MINUS key 11 permanently and press shortly the ON OFF key 8 afterwards The start speed 100 will be set Setting the Maximum Speed Press the PLUS key 12 permanently and press shortly the ON...

Page 20: ...Supply voltage 24V Stirring power 10 watts not adjustable Speed range 100 1000 rpm Control voltage rpm correlation linear OFF 0 25V ca 0 03V hysteresis 100 rpm 0 25V 0 28V 1000 rpm 9 4V MIXcontrol 20...

Page 21: ...h 0 10 volts interface is in the most cases a custom made version Therefore please ask ALWAYS before installation and using for the valid pin assignment Support info 2mag de D Sub 9 pole male connecto...

Page 22: ...rsion 5 1 4 3 3 PIN assignment MIXcontrol eco housing for cap rails Image 9 Pin assignment of MIXcontrol eco DINrail supply voltage 24 VDC 0 10V control voltage Brown white green yellow colors connect...

Page 23: ...gnment of MIXcontrol 20 40 DINrail Description functional elements of MIXcontrol 20 40 DINrail A Power socket 48 VDC B Socket for the stirrer control cable 1x for MIXcontrol 20 2x for MIXcontrol 40 C...

Page 24: ...eedbacks with comments No Command Feedback Comment 1 Start _A _AX _Z OK_START_A 2 Stop _A _AX _Z OK_STOP_A 3 SetRpm_ _A _AX _Z OK_ RPM_A 4 SendRpm _A _AX _Z OK_ RPM_A 5 SetPower_ _A _AX _Z OK_POWER _A...

Page 25: ...mmand Error codes Error 1 Unknown Command Error 2 Manual Mode Start Stop not possible Error 3 Parameter out of range set value not allowed 4 4 3 Hints to Parameter Operation The control unit is saving...

Page 26: ...d after starting the control unit in the remote mode The read out of the parameters are giving always back the parameters of the actual running mode Only by switching off the control unit by pressing...

Page 27: ...mmand to a batch file bits per second 9600 Baud 8 data bits 1 stop bit no parity bit flow control XON XOFF or None Note Flow control via hardware handshake is not working Minimum time distance between...

Page 28: ...2mag AG Page 28 of 44 Version 5 1 4 4 6 Screenshots Preferences HyperTerminal Screenshot 1 Screenshot 2...

Page 29: ...2mag AG Page 29 of 44 Version 5 1 Screenshot 3 Screenshot 4...

Page 30: ...mersed MIXdrive 60 MIXdrive 15 MIXdrive 6 MIXcontrol 40 MIXcontrol 20 MIXcontrol eco MIXdrive 1 MIXcontrol 20 MIXcontrol eco MIXdrive 1 eco MIXdrive 1 XS cuvetteMIXdrive MIXcontrol eco MIXdrive HT HT...

Page 31: ...only In the not allowed cases that only 1 3 5 7 stirring drives are connected the control unit will be destroyed immediately The accessory item distriBOX is available as 4 fold distriBOX 4 order no 4...

Page 32: ...g for immersion thermostats heating cooling Perfectly welded bath construction electro polished inside therefore easy to clean and care The framed ridge is formed as handle For operation temperatures...

Page 33: ...s and 200 C for the high temperature versions HT Operation in higher ambient temperatures can damage the stirring drive Water bath operation Please note the maximum operation temperature 50 C in water...

Page 34: ...t not be dipped in water or any cleaning solutions 2mag devices are generally maintenance free Due to their construction the 2mag devices are very robust and designed for the professional daily use We...

Page 35: ...9 89 14334369 E Mail info 2mag de Web www 2mag de Warranty Due to their construction the 2mag devices are very robust and designed for the professional daily use The magnetic drive works without any m...

Page 36: ...or causing stress dropping down The magnetism can be decreased by this Separate out this stirring bar and exchange it by a new one The control unit is not ready for operation despite the power connec...

Page 37: ...terial housing stainless steel Material sealing PUR Permitted operation conditions air 10 up to 50 C at 100 humidity Permitted operation Conditions water 50 C in water immersed Measurement WxDxH 12 5...

Page 38: ...ns 40 C up to 70 C 10 95 500 1060 hPa Protection category IP 68 Operating voltage 48 VDC Magnetic stirrer MIXdrive 6 15 60 MIXdrive 6 MIXdrive 15 MIXdrive 60 Order no 40006 40015 40060 Stirring points...

Page 39: ...70 C 10 95 500 1060 hPa Protection category IP 68 Operating voltage 48 VDC Magnetic stirrer MIXdrive 1 eco HT 1 HT MIXdrive 1 eco HT MIXdrive 1 HT Order no 40201 40301 Stirring points 1 1 Stirring vo...

Page 40: ...s Material housing stainless steel Material sealing PUR Permitted operation conditions air 10 up to 200 C at 100 humidity Permitted operation Conditions water 95 C in water immersed Measurement WxDxH...

Page 41: ...ng voltage 100 240 V 50 60 Hz 0 75 A 24 VDC Permitted storage conditions 40 C up to 70 C 10 95 500 1060 hPa Protection category IP 20 Control unit MIXcontrol 20 40 MIXcontrol 20 MIXcontrol 40 Order no...

Page 42: ...90421 Speed range 100 1 600 rpm 100 2 000 rpm Stirring power 20 watts 40 watts Stirring power steps Operating voltage 48 VDC Housing material plastic Measurements WxDxH 210 x 90 x 58 mm Weight approx...

Page 43: ...m Weight ca 0 3 kg ca 0 4 Permitted operation conditions 0 up to 40 C at 80 humidity Permitted storage conditions 40 C up to 70 C 10 95 500 1060 hPa Protection category IP 20 Image 13 Distributor dist...

Page 44: ...3 m Weight approx 0 1 kg Accessory Magnetic Stirring Bar ASTEROID 40 Magnetic Stirring Bar ASTEROID 40 Order no 44040 Shape triangle concave Material PTFE Measurement DxL 28 x 40 mm Weight ca 0 06 kg...

Page 45: ......

Page 46: ......

Page 47: ......

Page 48: ...w voltage directive 2014 35 EU incl their changes and the laws for the realization of the guideline into national law The declaration is valid under the following conditions The ambient conditions bei...

Reviews: