© 2mag AG
Page 24 of 44
Version: 5.1
4.4 PC-Interface – RS232
The control units MIXcontrol 20 RS232 (order no. 90210), MIXcontrol 20
DINrail RS232 (order no. 90221), MIXcontrol 40 RS232 (order no. 90410)
and MIXcontrol 40 DINrail RS232 (order no. 90421) include an interface
RS232 for external control by e.g. PC.
4.4.1 RS232 Commands
The RS232-commands are ASCII coded and can be sent to the MIXcontrol
with e.g. the program HyperTerminal which is coming with the Windows
operation system.
Listing of commands and feedbacks (with comments):
No. Command
Feedback
Comment
1
Start/(_A)/(_AX)/(_Z)
OK_START_A
2
Stop/(_A)/(_AX)/(_Z)
OK_STOP_A
3
SetRpm_????/(_A)/(_AX)/(_Z)
OK_????RPM_A
4
SendRpm/(_A)/(_AX)/(_Z)
OK_????RPM_A
5
SetPower_???/ /(_A)/(_AX)/(_Z) OK_POWER??? _A
6
SendPower/(_A)/(_AX)/(_Z)
OK_POWER??? _A
7
SetAdd_X_A
OK_SETADD_A_X
Change of unit address
A to X
8
SetDefault/(_A)/(_AX)/(_Z)
OK_SETDEFAULT_A
Reset to 350 rpm and
50% power
9
SendStatus/(_A)/(_AX)/(_Z)
OK_VXXXX_REM_ON
1. Address
2. Err or OK
3. SW versions no.
4. ReEM/MAN/OFF
(remote/manual/offline)
5. stirring or not
stirring
Spread sheet 2:
Commands – interface RS232
Each entering of the complete command has to be finished with the ASCII
code “Carriage Return (CR)”.
There is no determination of small and capital letters.