51
The self-adhesive
patches
, supplied in strips of 220, are used to
mask small areas which are not to receive flash treatment (such as
beauty spots). They must be applied after shaving and prior to the
application of the
gel
. It is then possible to apply flash treatment to
the entire area without worrying about
beauty spots. The
patches
are
removed at the end of the session.
The
clean
spray is used to clean and
maintain:
• The optical parts of the mobile head of the
applicator:
- External optical parts: spray directly and
wipe with a dry cotton cloth.
- Internal optical parts: Never spray directly
onto the internal optical parts. Apply the
spray to a dry cotton cloth, then clean the
filter (the flat element of red-coloured
glass) using this impregnated cloth.
Complete the cleaning using a dry part of
the cloth.
• The touch screen of the device: Never spray
directly onto the touch screen. Apply the spray
to a dry cloth, then clean the touch screen
using this impregnated cloth. Complete the
cleaning using a dry part of the cloth.
USING THE ACCESSORIES
The
extractor
tool is used to separate the mobile head of your
applicator for the cleaning of the optical parts or the replacement
of the cartridge.
The
fun
stencils are used to mark out zones which are not to receive
flash treatment, allowing localized hair growth to be retained in fun
shapes. They are to be applied after the complete shaving of the
area and the application of
gel
. The presence of
gel
will retain
the patches in position, to a degree. It is possible for flash treatment
to overlap the edge of these stencils, in order to ensure the clear
demarcation of the outlines of the shape required.
EXTRACToR
FUN
(option)
CLEAN
Made in China
Made in France
Made in France
Made in France
All these products can be found on our website at www.e-swin.com
or from your authorised distributor.
The
special filter
is designed for highly pigmented skins. It is
supplied in an individual plastic casing.
special FILTeR
Made in China
The spray must not be used until the device has been
unplugged and the optical parts have cooled. If any operation
is to be undertaken after using
, you must wait until
the fan in the applicator has shut down completely before
unplugging the base. Amongst other functions, this will
ensure the correct cooling of the optical components.
PAtcheS
EYE MASK
Made in China
The
eye mask
shells must be worn by persons treated and
adjusted correctly. These shells protect the eyes of the patient.
Disinfect the protective shells after each session.