Code Fault reaction
Description of fault
Possible cause
Ter-
minal
on
BLM
Input
code
for
diag-
nose
5060 Output switched
off, no potential
15 on machine,
control is
working, engine
is stopped or
cannot be started
Output relay K 11, change-
over of potential 15
Too high current flow out of
this output
Output was switched off!
Excessive current flow in cur-
rent path, probably because of
a defective coil or a short cir-
cuit to ground
X3:07
-
5061 Output switched
off, no potential
15 on machine,
control is
working, engine
is stopped or
cannot be started
Output relay K 11, change-
over of potential 15
Short-circuit current flow out
of this output
Output was switched off!
Short circuit to ground in the
current path
Lines rubbed through
X3:07
-
5062 Output switched
off, no potential
15 on machine,
control is
working, engine
is stopped or
cannot be started
Output relay K 11, change-
over of potential 15
No or too low current flow
out of this output
Wire breakage in current path
Current path connected to
+12V
X3:07
5060
5061
5062
5063 Output switched
off, no potential
15 on machine,
control is
working, engine
is stopped or
cannot be started
Output relay K 11, change-
over of potential 15
Although the output is
switched off, voltage is
present
Current path connected to
+12V
X3:07
5060
5061
5062
5070 Output switched
off, engine
cannot be started
Output relay K 39, starter
Too high current flow out of
this output
Output was switched off!
Excessive current flow in cur-
rent path, probably because of
a defective coil or a short cir-
cuit to ground
X3:06
-
5071 Output switched
off, engine
cannot be started
Output relay K 39, starter
Short-circuit current flow out
of this output
Output was switched off!
Wire breakage in current path
Current path connected to
+12V
Lines rubbed through
X3:06
-
5072 Output switched
off, engine
cannot be started
Output relay K 39, starter
No or too low current flow
out of this output
Wire breakage in current path
Current path connected to
+12V
X3:06
5070
5071
5072
5073 All outputs
switched off,
engine stopped,
safety relay
switched off
Output relay K 39, starter
Although the output is
switched off, voltage is
present
Current path connected to
+12V
X3:06
5070
5071
5072
Appendix – List of fault codes
D.ONE
177
Summary of Contents for D.ONE
Page 2: ...2...
Page 7: ...1 Introduction Introduction D ONE 7...
Page 11: ...2 Technical data Technical data D ONE 11...
Page 16: ...Technical data Noise data D ONE 16...
Page 17: ...3 Concerning your safety Concerning your safety D ONE 17...
Page 50: ...Concerning your safety Signage D ONE 50...
Page 51: ...4 Indicators and control elements Indicators and control elements D ONE 51...
Page 60: ...Indicators and control elements Remote control D ONE 60...
Page 61: ...5 Checks prior to start up Checks prior to start up D ONE 61...
Page 69: ...6 Operation Operation D ONE 69...
Page 95: ...7 Loading transporting the machine Loading transporting the machine D ONE 95...
Page 101: ...8 Maintenance Maintenance D ONE 101...
Page 142: ...Maintenance As required D ONE 142...
Page 143: ...9 Setting up refitting Setting up refitting D ONE 143...
Page 148: ...Setting up refitting Teaching the BOSS safety field system D ONE 148...
Page 149: ...10 Troubleshooting Troubleshooting D ONE 149...
Page 167: ...11 Disposal Disposal D ONE 167...
Page 169: ...12 Appendix Appendix D ONE 169...
Page 189: ......
Page 190: ......