Copper containing materials (copper lines, brass items) should be
avoided, because they can cause catalytic reactions in the fuel with
subsequent depositing in the injection system.
8.3.3 Coolant
Always use a mixture of anti-freeze agent and clean, dehardened
water with a mixing ratio of 1:1.
Under particularly extreme temperature conditions you should con-
sult our customer service concerning the anti-freeze agent to be
used.
There are various types of anti-freeze agents available. For this
engine you should use ethylene glycol.
Before filling in the coolant mixed with anti-freeze agent the radi-
ator must be flushed with clean water. This procedure should be
repeated two to three times to clean the inside of radiator and
engine block.
NOTICE!
Danger of engine damage!
–
Do not mix different coolants and additives of
any other kind.
Mixing the coolant:
n
Prepare a mixture of 50% anti-freeze agent and 50% low min-
eral, clean water.
n
Stir well before filling it into the radiator.
n
The method of mixing water and anti-freeze depends on the
brand of the anti-freeze agent (see standard SAE J1034 and
also standard SAE J814c).
Add anti-freeze agent:
n
If the coolant level drops because of evaporation,only clean
water is to be used for topping up.
n
In case of leakages you must always fill in anti-freeze agents of
the same brand and the same mixing ratio.
Do not use any radiator cleaning agent after the anti-freeze agent
has been mixed in. The anti-freeze agent also contains a corrosion
protection agent. If this mixes with cleaning agent it may cause the
development of sludge, which could damage the cooling system.
Anti-freeze concentration
Freezing point
50 %
-37 °C (-35 °F)
Maintenance – Fuels and lubricants
D.ONE
107
Summary of Contents for D.ONE
Page 2: ...2...
Page 7: ...1 Introduction Introduction D ONE 7...
Page 11: ...2 Technical data Technical data D ONE 11...
Page 16: ...Technical data Noise data D ONE 16...
Page 17: ...3 Concerning your safety Concerning your safety D ONE 17...
Page 50: ...Concerning your safety Signage D ONE 50...
Page 51: ...4 Indicators and control elements Indicators and control elements D ONE 51...
Page 60: ...Indicators and control elements Remote control D ONE 60...
Page 61: ...5 Checks prior to start up Checks prior to start up D ONE 61...
Page 69: ...6 Operation Operation D ONE 69...
Page 95: ...7 Loading transporting the machine Loading transporting the machine D ONE 95...
Page 101: ...8 Maintenance Maintenance D ONE 101...
Page 142: ...Maintenance As required D ONE 142...
Page 143: ...9 Setting up refitting Setting up refitting D ONE 143...
Page 148: ...Setting up refitting Teaching the BOSS safety field system D ONE 148...
Page 149: ...10 Troubleshooting Troubleshooting D ONE 149...
Page 167: ...11 Disposal Disposal D ONE 167...
Page 169: ...12 Appendix Appendix D ONE 169...
Page 189: ......
Page 190: ......