10.7 Remote control faults (radio operation)
Prerequisite:
n
Function of the remote control in cable operation without any
interference
n
No steel rope or metal attachments on the machine (radio con-
nection interference)
Fault
Possible cause
Remedy
Machine does not
respond
Aerial defective or wrong one installed
Have examined by a specialist; replace if
necessary
Receiver not or incorrectly connected
Check the plug-in connection between
receiver and machine
Receiver and radio remote control have
different system numbers
Check the system numbers; use the radio
remote control with identical system
number
Battery empty or defective
Charge or replace the battery
Distance between machine and radio
remote control is too great
Reduce the distance
Operating mode toggle switch defective
Have examined by a specialist; replace if
necessary
Receiver or radio remote control defec-
tive
Have examined by a specialist; replace if
necessary
Ignition key in posi-
tion "I", display
module operative,
but engine cannot
be started
Battery empty or defective
Charge or replace the battery
Receiver or radio remote control defec-
tive
Have examined by a specialist; replace if
necessary
Engine stops for no
reason
Battery empty or defective
Charge or replace the battery
Interference caused by other radio sig-
nals
Check close vicinity for other radio sig-
nals (e.g. airport, construction crane); if
necessary, move machine by means of
cable operation
Aerial defective or wrong one installed
Have examined by a specialist; replace if
necessary
Distance between machine and radio
remote control is too great
Reduce the distance
Operating mode toggle switch defective
Have examined by a specialist; replace if
necessary
Emergency stop switch actuated or
defective
Pull out the emergency stop switch
Have examined by a specialist; replace if
necessary
Troubleshooting – Remote control faults (radio operation)
D.ONE
161
Summary of Contents for D.ONE
Page 2: ...2...
Page 7: ...1 Introduction Introduction D ONE 7...
Page 11: ...2 Technical data Technical data D ONE 11...
Page 16: ...Technical data Noise data D ONE 16...
Page 17: ...3 Concerning your safety Concerning your safety D ONE 17...
Page 50: ...Concerning your safety Signage D ONE 50...
Page 51: ...4 Indicators and control elements Indicators and control elements D ONE 51...
Page 60: ...Indicators and control elements Remote control D ONE 60...
Page 61: ...5 Checks prior to start up Checks prior to start up D ONE 61...
Page 69: ...6 Operation Operation D ONE 69...
Page 95: ...7 Loading transporting the machine Loading transporting the machine D ONE 95...
Page 101: ...8 Maintenance Maintenance D ONE 101...
Page 142: ...Maintenance As required D ONE 142...
Page 143: ...9 Setting up refitting Setting up refitting D ONE 143...
Page 148: ...Setting up refitting Teaching the BOSS safety field system D ONE 148...
Page 149: ...10 Troubleshooting Troubleshooting D ONE 149...
Page 167: ...11 Disposal Disposal D ONE 167...
Page 169: ...12 Appendix Appendix D ONE 169...
Page 189: ......
Page 190: ......