Fault
description
Cause
Remedy
0001 = OK, inclination of machine less than 45°
Shows the switching state of the
inclination switch
0000 = No signal, machine inclined more than 45°, or
switch defective
0001 = OK, inclination of machine less than 45°
5040
Output bia winding of shut-down
solenoid, Y 13
Display value = output voltage in Volt
Voltage at output
Display value = output voltage in Volt
5041
Output bia winding of shut-down
solenoid, Y 13
Display value = output current in Amperè
Current at output
Display value = output current in Amperè
5042
Output bia winding of shut-down
solenoid, Y 13
0000 = Output not triggered
0001 = Output triggered
Logic level of control
0000 = Output not triggered
0001 = Output triggered
5050
Output relay K 114, engine speed
solenoid
Display value = output voltage in Volt
Voltage at output
Display value = output voltage in Volt
5051
Output relay K 114, engine speed
solenoid
Display value = output current in Amperè
Current at output
Display value = output current in Amperè
5052
Output relay K 114, engine speed
solenoid
0000 = Output not triggered
0001 = Output triggered
Logic level of control
0000 = Output not triggered
0001 = Output triggered
5055
Enable parameter change ECO-
mode
5056
Confirm parameter change ECO-
mode
Subsequently switch off the ignition!
5057
ECO-mode off
Enter code number 5055 first!
5058
ECO-mode on
Enter code number 5055 first!
5059
Display of ECO-mode setting
0 = ECO-mode off
1 = ECO-mode on
5060
Output relay K 11, potential
changeover
Display value = output voltage in Volt
Voltage at output
Display value = output voltage in Volt
5061
Output relay K 11, potential
changeover
Display value = output current in Amperè
Appendix – Input codes for BLM control
D.ONE
184
Summary of Contents for D.ONE
Page 2: ...2...
Page 7: ...1 Introduction Introduction D ONE 7...
Page 11: ...2 Technical data Technical data D ONE 11...
Page 16: ...Technical data Noise data D ONE 16...
Page 17: ...3 Concerning your safety Concerning your safety D ONE 17...
Page 50: ...Concerning your safety Signage D ONE 50...
Page 51: ...4 Indicators and control elements Indicators and control elements D ONE 51...
Page 60: ...Indicators and control elements Remote control D ONE 60...
Page 61: ...5 Checks prior to start up Checks prior to start up D ONE 61...
Page 69: ...6 Operation Operation D ONE 69...
Page 95: ...7 Loading transporting the machine Loading transporting the machine D ONE 95...
Page 101: ...8 Maintenance Maintenance D ONE 101...
Page 142: ...Maintenance As required D ONE 142...
Page 143: ...9 Setting up refitting Setting up refitting D ONE 143...
Page 148: ...Setting up refitting Teaching the BOSS safety field system D ONE 148...
Page 149: ...10 Troubleshooting Troubleshooting D ONE 149...
Page 167: ...11 Disposal Disposal D ONE 167...
Page 169: ...12 Appendix Appendix D ONE 169...
Page 189: ......
Page 190: ......