7.4 General procedure for setting up multiple configurations
26
1) Unlock the components (see section 7.5.1), sensors and
display units, to be used in the multiple configuration.
2) Switch off all hardware.
1) Switch on Master unit and use
to check that no foreign element is
present on the Master radio channel. (see section 7.5.5).
2) If needed select another channel (see section 7.5.6).
1) Select a unit to be the Master Display Unit in the
configuration.
2) Select the unit(s) that will be the Slave units in the
configuration.
3) Check / Set appropriate mode (see section 7.5.4).
The components to be included, using the Master unit
channel, are identified by the Master and automatically
associated with a multiple configuration.
Check the associations using
1) Switch off the Master unit.
2) Switch on all other
components apart from the
Master unit.
3) Switch on Master unit.
Sensors see : section 7.5.7.1 a
D. units see: section 7.5.7.2 a
Unidentified sensors.
Add one or more sensors working
on a different radio channel to the
Master unit.
Unidentified display units.
Add one or more Slave display
units working on a different radio
channel to the Master unit.
See 7.5.7.1 b
See 7.5.7.2 b
GB