16
6.2.4.5 MAX Function (Peak stress save)
Reset MAX value to current
stress level
Peak load function:
From the Standard screen, go to
the MAX icon.
Confirm with
The "in progress" screen appears
while the display unit dialogues
with the sensor to change to
"Peak Load" mode - 32 measures
per second.
ESC
Return to standard display
No action
No action
Reset MAX value to current
stress level
Peak load function:
The peak load value is displayed.
The barograph represents 100%
of sensor capacity.
The cursor indicates the peak
value of stress.
The moving black line shows the
immediate stress value.
ESC
Return to standard display
Enable MAX window selection
mode
Enable MAX window selection
mode
Display
Action
Comments
Confirm selection
Advanced Peak load functions:
In this mode you can saves the
peak stress set saves.
Using the arrows and from the
MAX window, select the icon:
Diskette and confirm with
to
save.
The printer icon is not used in this
version.
ESC
Return to MAX display
Move clockwise from icon to
icon
Move anti-clockwise from icon
to icon
5
6
7
GB
Summary of Contents for LLX2
Page 37: ......
Page 73: ......
Page 109: ......
Page 145: ......
Page 147: ...13 3 39 36 28 30 27 29 6 7 4 B 4ʼ 35 54 Chap 8 kN kg t Lbs ton daN nopsis chaltbild ...