36
12 PRODUCT MARKING
All of the indicators and labels placed on the product by the manufacturer must be kept clearly readable.
Should they be lost or damaged, replace these indicators and labels before continuing to use the
appliance. Tractel
®
can provide new labelling on request.
Trouble
Possible causes
Solutions
Dead sensor batteries
Sensor switched off or switched
to take standby mode.
Sensor too far from display unit.
Network conflict.
Replace batteries
Switch off display unit, switch on
sensor, switch on display unit.
Bring appliances closer together
Check network configuration
(advanced functions section
6.3.2.4).
Sensor subject to compression
or torsion.
Negative imbalance of gauge
bridge.
Eliminate compression stress
on sensor.
Contact the after-sales service.
Switch on a Master display unit
on a site where several LLXh
are already operating.
Select a other channel (see
§ 7.5.6).
A connection has been made
using an USB lead between the
display unit and the PC without
having installed the Tractel
®
software.
Use the Tractel
®
"PC Link"
option.
Ineffective display
Malfunction of the display.
Keep the ON/OFF key pressed
during 10 sec.
Reboot both load cell and
display (see 6.1).
Marking sensor
Marking
display
Marking battery
charger
GB