Dyadic Systems – Mechatronics Cylinder Manual
MF
-005500-EN-31/63
SCN6 Models (20Kgf, 40kgf, 50kgf & 60kgf Types)
MODEL
SCN6-020
SCN6-040
SCN6-050
SCN6-060
050 100 150 200 250 300 050 100 150 200 250 300 050 100 150 200 250 300 050 100 150 200 250 300
Stroke (mm)
50
100
150
200
250
300
50
100
150
200
250
300
50
100
150
200
250
300
50
100
150
200
250
300
Life
Other than seal
3 years after the delivery, or 10,000 km operation under the use within the specs.
Seals
6 months, or 2,500 km run (Dust Proof Model Only)
Max. Thrust (N) / (kgf)
200 / 20.2
400 /40.8
500 / 51.0
650 /66.3
Max. vertical carriable wt at power ON
14
28
30
45
Push mode max. Thrust (N)/(kgf)
140 / 14.2
280 / 28.5
350 / 35.5
450 / 45.9
Max. Speed (mm/s) * note 1
200
100
100
100
Repeatability (mm)
± 0.1
Backlash (mm)
0.3
Radial Load Capacity (N)
30
20
10
10
10
10
30
20
10
10
10
10
75
50
25
18
15
12
75
50
25
18
15
12
Rod Diameter (mm)
Ø 22
Rod Tip Thread
M14 Pitch 1.5 (303SS)
Program Capacity
16 Motions
Power Supply
DC24V ± 10% (Drive Power max. 3.0 Amps, Control power max. 0.2A)
Parallel
DC24V type DI/DO Interface (Connector PIO)
Input
Names
Position number (4 bit binary: PC1,PC2,PC4,PC8)
Start (CSTR), Axis Movement Interlock (ILK)
Input current
Max. 4mA / port
I/O Parallel
DC24V type DI/DO Interface (Connector PIO), Position complete(PFIN/INP),
Output
Names
Completed Position Number (4bit binary: PM1,PM2,PM4,PM8),
Homed signal(ZFIN), Zone signal(ZONE), Alarm (ALM)
Output current
Max. 10mA / port
Serial Signal
Serial Interface (Connector SIO)
+5V, 0V, S+, S-
Protection function
Over speed, Main power over voltage, abnormal voltage,
Overload, Sensor abnormal, Servo abnormal, Encoder wire disconnected
Operate Temperature
0 ~ 40°C
Ambience Storage Temperature
-20 ~ 60°C
Ope/Storage Humidity
≤
90% RH, non-condensing
Vib./shock Duravility
2G/10 times
Protection
IP-40 equivalent (Standard), IP-54 (Dust proof sealed model)
Weight (kgs)
1.6
1.9
2.2
2.5
2.8
3.1
1.9
2.2
2.5
2.8
3.1
3.4
1.9
2.2
2.5
2.8
3.1
3.4
1.9
2.2
2.5
2.8
3.1
3.4
Functions
- Positioning with speed, Accele
- Increment movement
- Stroke Limit end set
- Zone Signal output
- Push Force Mode
- Home Direction Set
- Suitable Auto Max. Accel
- Zone Signal output
- Complete signal range set
- Servo Gain Adjust
Notes: (*1) Typical data (*2) Stroke 200mm, 250mm and 300mm are available.