Dyadic Systems – Mechatronics Cylinder Manual
MF
-005500-EN-11/63
1.2.2 Name Plate
The name plate is located at the back of the Mech. Cylinder. (Please refer to 1.2.1)
2. Safety Notes
(1)
Please use the following voltages and power supplies of sufficient capacity:
Using N axes, 2 x N (amps) power supply capacity is not necessary if the timing of axis
movements varies slightly.
(2)
Incorrect wiring may damage the equipment.
(3)
Please do not change wiring when the power is on. Please remove and/or plug in parallel connectors (PIO)
when the power is turned off.
(4)
Please install the unit in a good place for sensitive electrical equipment. (Good thermal radiation, low vibration,
low shock)
(5)
Please make sure to provide protection from electrical noise. If the unit receives noise, the cylinder may
vibrate and/or make inaccurate movement.
(6)
Please do not test the unit for voltage durability or electro-magnetic susceptibility.
(7)
Please hold the connector when disconnecting the cables.
(8)
Please note that the coordinate system for the forward homing mode is negative and the reverse homing
mode is positive. This also applies to the push force mode. This is especially important to keep in mind for
Teach Pendant operation.
(9)
The short cables protruding from the motor are not high flex cables.
Notes for SCLL6 Model
(10)
Ensure the system is designed within the specifications of max moment load on the slider table.
(11)
The acme screw in the SCLL6 is exposed to the ambient environment. Therefore it requires an application of
grease approximately every 6 months. The recommended grease is Lithium type No.2. Remove the top
cover by removing the 4 cover screws, and apply grease on the slider screw. Move the carriage back and
forth several times to distribute the grease. Please do not apply grease to the guide bushings of the carriage.
Intelligent Cylinder
Model Name & Code
Dyadic Systems Co.,Ltd
S/N
MODEL
Serial Number
MADE IN JAPAN
Models Power
type
Power
SCN5- Built-in Amp,
SCLL5- Built-in Amp,
SCLG5- Built-in Amp,
SCLT4- Built-in Amp
DC24V+/-10% (Max. 2A)
SCN6, SCLL6, SCLT6
Motor
DC24V+/-10% (Max. 3A)
Control
DC24V+/-10% (Max. 0.2A)
SCLL5- External Amp,
SCLG5- External Amp,
SCLT4- External Amp
Motor
DC24V+/-10% (Max. 2A)
Control
DC24V+/-10% (Max. 0.2A)