61
COVER
60
The designated connection terminal blocks need to be used to connect the
‘DURACOVER’ Cover System to the LINK Master.
DLM-600 cover wiring
6.1.2. Multi-Brand Cover wiring instructions
A Multi-Brand cover is supported by simulating the open and close Key-
Switch functions with use of the Relay A and B terminals on the LINK Master.
When a Key-switch is used it needs to be connected to the LINK Master, this
signal will be received and passed on by the LINK Master over the Relay A
and B to the stand alone Multi-Brand controller.
The LINK Master is ‘sort of’ in the middle of the Multi-Brand cover. This
information is important for the LINK Master to make the Smart Rules work
correctly.
DLM-600 Multi-Brand Cover wiring
6.1.3. Key Switch installation
Both the DURACOVER Cover System and the Multi-Brand cover can also be
operated with a key Switch.
The designated connection terminal blocks need to be used to connect the
Key Switch to the LINK Master.
•
The lead wires of the key-switch must be connected to
o
Terminal blocks 23 and 24 - Closing the contact will OPEN
the
cover
o
Terminal blocks 25 and 26 - Closing the contact will CLOSE
the
cover
DLM-600 Key Switch wiring