Using Filling in Manual mode.
•
Filling is only available when Relay B is configured as Filling output
(
→
2.2.3.), if filling is activated without the correct configuration
of Relay B, the led will blink 3 times fast.
•
When filling is active, the following changes are made:
•
Filter pump is enabled.
•
Filling valve is activated.
•
The filling will automatically be disabled after 3 hours.
•
Filling can in manual mode be controlled by pressing the
filling button on the keypad.
2.4. Updating
2.4.1. Controller
The LINK Master controller can be updated in two ways.
•
The first is an automated process whereby the firmware of the LINK
Master and all the devices will be updated when the gateway
receives a new firmware image, containing all the firmware of the
connected devices.
•
The second is a manual procedure whereby an SD-card containing
the firmware update (LINK Master only) is inserted in the SD-card
slot on the controller board. (only available for authorized House of
DURATECH support staff)
o
Update procedure:
-
Turn OFF the LINK Master
-
Insert µSD Card
-
Turn on LINK Master
-
LINK Master controller will update (8 bottom leds
will have a `wave` animation while updating)
-
When the update is complete, the LINK Master will
automatically
restart.
-
You can remove the µSD card.
o
NOTE: The manual procedure will only update the
LINK Master. It will NOT update the attached devices.
Be careful that the model versions of all devices are still
compatible with the updated LINK Master.
2.4.2. Gateway
The LINK Master gateway can also be updated.
•
The gateway will automatically download, install, validate and
reboot itself when connected to the internet when a new firmware
version is available.