43
POOL LIGHT
42
3.3.2. App
3.3.3. DMX controller operation
When using a DMX controller for operating the pool light, the functionalities
of the LINK Touch or the DuraCloud App will no longer be active.
3.3.4. RS485 command set
Function
Command
Remark
Example
Avail-
able in
ON/
OFF
mode
Avail-
able
in PLC
mode
Lamps OFF
PL0
All lamps OFF
X
X
Lamps ON
PL1
All lamps ON
X
X
Program UP
PsU
Jump to next program
X
X
Program Down
PsD
Return to previous program
X
Set Program
PSxx
xx is the decimal repre-
sentation of the program
number (01-14)
PS06 = jump to program 6
X
Auto sync pro-
cedure
PsS
Exectures the autosync
procedure
X
X
White 1
PW1
Jump to white 1 (program
12)
X
White 2
PW2
Jump to white 2 (program
13)
X
White 3
PW3
Jump to white 3 (program
14)
X
Set RGB
PCrrrgggbbb
rrr,ggg,bbb are the decimal
representation of the RGB
value (with leading zero’s)
1) PC255128064 = Full output-
level on Red color, half out-put
level on Green color, ¼ output
level on Blue color
2) PC255255255
= All colors at full
output level
3) PC000000000
= All colors OFF
X
Set Dim value
PDxxx
Set the OUTPUT value of
the lamp im % (000 - 100)
PD075 = 75% output level (on
all LED’s)
X
Set DMX startAd-
dress
PAxxxyz
Y = ‘e’ or ‘E’
PA035E = set DMX start ad-
dress to 35 [35(R), 36(G), 37(B)]
X
Set color in
percentage
Pprgbe
Variable size, rgb = ASCII
0-255, e = end character
Pp25050100e = Red 25%,
Green 50%, Blue 100%
X
Set color in hex
Pcrgbe
Variable size, rgb = ASCII
0-255, e = end character
Pc64128255e = Red 25%,
Green 50%, Blue 100%
X
ON/OFF relay
control
RPMx
x = 1 (ON), 0 (OFF)
PRM1 = Relay ON/OFF control
ON
X
X
Color tempera-
ture
PTxyz
x = ten thousand; y = thou-
sand; z = hundred
PT035 = Set white color
temperature to 3500K (in steps
of 500K)
X