31
LINK M
ASTER
30
2.3.3. Automatic mode
By default the LINK Master is in Automatic mode. In this mode the LINK
Master will follow the schedule which is behind the selected Pool mode.
(
→
2.2.8.)
Returning to Automatic mode
•
From Manual mode the LINK Master can go to Automatic mode by
pressing the MANUAL button on the keypad.
•
From Pairing mode the LINK Master can go to Automatic mode by
pressing the DURALINK button on the keypad.
Using Cleaning in Automatic mode.
•
Cleaning can be (de)activated via a short press on the keypad
cleaning button.
•
When Cleaning is active, the following changes are made:
•
Filter pump will be set in BOOST
•
Purification will be disabled if configured as: `on filtration`
in the DuraCloud App pool settings.
•
Cleaning will be disabled automatically after 6 hours.
Using Filling in Automatic mode.
•
Filling is only available when Relay B is configured as Filling output
(
→
2.2.3.),if filling is activated without the correct configuration
of Relay B, the led will blink 3 times fast.
•
When filling is active, the following changes are made:
•
Filter pump is enabled.
•
Filling valve is activated.
•
The filling will automatically be disabled after 3 hours.
•
Filling can manually be controlled by pressing the filling button on
the keypad or by a dedicated ‘level’ sensor sending a digital signal
(connected to input C).
When the ‘level’ sensor is activated the signal sent to input C will enable
the filling cycle. This cycle enables filling for 3 hours followed by a stop of
9 hours. The 3 hours of filling will start again after the stop of 9 hours if the
signal for filling remained active. If the signal is no longer active it will stop
the cycle. A new filling cycle will start once a new signal is received.
2.3.4. Manual mode (service mode)
The Manual mode (service mode) is used to give manual access to each
individual device. The functioning of each device can be enabled or disabled
manually with the Keypad buttons, LINK Touch or DuraCloud App.
The Manual mode can be activated in two ways.
1.
Pressing the button Manual will activate the Manual mode. This will
instantly disable/stop all devices and will give access to enable every
device manually.
2.
When the LINK Master is in automatic mode, pressing any of these
buttons Heating/ Filtration/ Aux/ Sensors/ Relay A/ Relay B will
bring all devices in manual mode.
In the background the current states of all devices (Heating/ Filtration/ Aux/
Sensors/ Relay A/ Relay B) will be copied to the manual mode, and for the
button which was pressed the command will be executed.
Be aware that in manual mode devices will still switch ON other devices to
start operating correctly. (example; when manually switching on the heat
pump the filter pump will also be activated)
The LINK Master will continue to run in the Manual mode until this
mode is disabled by pressing the “manual” button on the keypad or
automatically disabled after 3 hours.
Using Cleaning in Manual mode.
•
Cleaning can be (de)activated via a short press on the keypad
cleaning button.
•
When Cleaning is active, the following changes are made:
•
Filter pump will be set in BOOST
•
Purification will be disabled if configured as: `on filtration`
•
Cleaning will be disabled automatically after 6 hours.
All other devices will continue to work as set.