OFF

ON

Open Window

Wed. 11:00h

21

.5°C

Set point:

OFF

ON

Self Adaptive

OFF

ON

EASY mode

OFF (100%)

75%

50%

20%

LowSurfaceTemp

Wed. 11:00h

21

.5°C

Set point:

COMFORT

EASY

set temp

21

.5°C

Set point:

Wed. 11:00

Status      ON

Change

Password

Runback Config

Setback

Max. Temp.

Runback

Confirm

OK  CANCEL

RESET

LST 23%

Wed. 11:00h

21

.5°C

Set point:

The  Open  window  setting 

will  turn  the  heating  of  the 

towel rail off if the unit detects 

a rapid drop in temperature 

over a short period of time. 

To  re-activate  the  heating 

if the open window function 

has  activated  press  any 

button the towel rail. 

If  the  temperature  rises 

above the minimum detected 

temperature then the heater 

will reactivate and turn the open window function 

off (i.e. the window was closed).

If  this  function  comes  on  frequently  e.g.  in  an 

area  where  there  is  an  external  doorway,  it  is 

recommended to turn the open window function 

off. To turn on/off use the +/- buttons and confirm 

with 

Mode/OK

.

The  Self  Adaptive  setting 

will  allow  the  towel  rail  to 

calculate  the  optimum  time 

to  start  the  heating  cycle 

when running in Program 

mode.

 

If  this  setting  is  turned 

on  it  will  be  shown  in  the 

Notification  area  and  the 

heating will come on before  

the  programmed  starting 

time  so  that  the  room  is  at 

the  correct  temperature 

at 

the programmed starting time. To turn on/off use 

the +/- buttons and confirm with 

Mode/OK

.

The 

Low 

Surface 

Temperature  (LST)  menu 

will  allow  the  output  of  the 

heater  to  be  limited  to  a 

lower  setting  to  prevent 

the  surface  of  the  heater 

becoming too hot. 

It  is  recommended  that  if 

the LST function is activated 

then the towel rail should be 

locked  with  a  non-standard 

password after activation to 

prevent  the  function  being 

turned off.

(See Password Section for details on changing 

the factory default password).

To cycle between the different outputs use the 

+/- buttons and confirm the selection with 

Mode/

OK.

EASY  Mode  is  a  simple 

mode  of  operation  where 

by only the + and – buttons 

on  the  towel  rail  operate  to 

increase  or  decrease  the 

temperature. The 

Mode/OK

 

button is de-activated. 

When  running  in  Easy 

mode  the  screen  will  show 

EASY in the notification area 

to let the user know that the 

mode is active. 

To exit EASY mode press 

and hold the CONFIG button 

for  10  seconds,  then  select 

“off”,  using  the  +/-  button 

and  confirm  by  pressing 

Mode/OK.

Runback:  See  Runback 

Section on page 14

Password:  See  Password 

Section on page 14

Resetting  the  towel  rail 

will return all settings to the 

factory defaults and will also 

delete  any  ‘pairing’  with  a 

Gateway.

To activate the RESET feature select “OK” using 

the  +/-  buttons  and  then  press  the 

Mode/OK

 

button to confirm.

 The first press of any button will wake up the towel rail any further 

button presses will activate the function required. 

Summary of Contents for Colorado DGi+ 450

Page 1: ...E1400298 20210204 NOTE A qualified electrician must carry out the electrical installation of this towel rail The electrical installation must comply with current UK regulations Any claim on the warra...

Page 2: ...in operating modes 8 Set auto temperatures 8 Setting the time and date 8 Entering a program 9 Boost 10 Display settings 10 Programming with APP 11 Keypad Locking Anti Tamper 11 Advanced settings 11 Pa...

Page 3: ...mended to install this towel heater so that the lowest heating bar is at least 600 mm above the floor This appliance must only be connected according to the rules and standards in application by an au...

Page 4: ...Scan this QR code to access to the download It is also possible to programme each towel rail individually without theApp by using the built in controls and screen This may be convenient for single hea...

Page 5: ...tches and other control devices can be touched by a person in the bathtub or shower This product is rated as IP44 and can be located in zone 2 the area stretching 60cm outside the perimeter of the bat...

Page 6: ...etween the 2nd and 3rd horizontal tubes from the bottom STEP 1 First the 4 supports are placed on the towel rail take a piece B fix the piece D with the screw C and insert it between two tubes from th...

Page 7: ...tivate the function required Switching ON Once the towel rail has been mounted on the wall and correctly connected to the mains electricity power supply press the main On Off button on the left side o...

Page 8: ...rail is in AUTO mode the temperature can be adjusted by pressing the buttons This change will remain active until either the next programme change or until midnight when the temperature will revert to...

Page 9: ...ram into the towel rail first select the day of the week in the upper left corner of the programming screen by using the button and press Mode OK change the day to the day you want to program using bu...

Page 10: ...tween 1 hour and 24 hours using the buttons To return to the BOOST screen press the CONFIG button You can quickly adjust the duration with the BOOST button Each press will increase the duration of BOO...

Page 11: ...Settings Chapter for further details on changing passwords To Lock the towel rail Press and hold the and buttons until the lock screen appears 40 Enter the password on the screen using buttons followe...

Page 12: ...at the programmed starting time To turn on off use the buttons and confirm with Mode OK The Low Surface Temperature LST menu will allow the output of the heater to be limited to a lower setting to pre...

Page 13: ...comes with a Runback mode for use when the heater will be installed in areas where restricted user control is required When Runback Mode is active it allows the user to set the towel rail to run for...

Page 14: ...heater is installed can fall to outside of the Runback operation This temperature can be set between 7 C minimum and 0 5 C less than the Runback temperature set point When Setback is operational the s...

Page 15: ...heating system is not accessible from the app However the running schedule remains in the towel rail memory and continues with the last user setting so long as the lithium battery is not flat The Lit...

Page 16: ...t mode temperature 21 C Boost mode time 1 hour Low Surface Temperature Disabled Password status Activated Password 0000 Units C Keyboard Unlocked Easy mode Disabled Runback mode Disabled Setback Disab...

Page 17: ...elmax 0 0005 kW 0 0005 kW At minimum heat output elmin 0 0005 kW 0 0005 kW In standby mode elSB 0 0005 kW 0 0005 kW Type of heat output room temperature control Electronic room temperature control pl...

Page 18: ...18 NOTES...

Page 19: ...19 NOTES...

Page 20: ...posed of with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types o...

Reviews: