11
PAIRED WITH
GATEWAY
Next Program ON Time
Starts at:Tue. 20:00
Set point:
21
.5°C
Wed. 11:00
ENTER CODE
TO LOCK
- - - - OK
LOCKED
ENTER CODE
TO UNLOCK
- - - - OK
Units
Control Type
Temp Offset
Open Window
Self Adaptive
ADVANCED
SETTINGS
Celsius
Fahrenheit
UNITS
PID
Hysteresis
.25°C
Hysteresis
.35°C
Hysteresis
.5°C
Hysteresis
.75°C
Control Type
Display temp
22.5°C
1.1°C
Temp. Offset
PROGRAMMING WITH APP
To programme a towel rail with a
Gateway the heater must be paired to
the Gateway. In order to complete this operation
the pairing/discovery mode of the Gateway should
be activated. To complete this process, press the
Link button on the Gateway for 2 seconds.
(Details
of this procedure can be found in the Tevolve
Gateway instruction manual)
. Alternatively press
+ icon in the App and follow the instructions.
Once this is done, press and hold the
Mode/OK
button in the app for 3 seconds while the towel
rail is in one of the main modes (OFF, AUTO,
MANUAL).
Once the pairing process completes the display
will show “Link” with an antenna and then display
the same information in the upper right corner of
the screen.
The towel rail is now ready to accept programme
instructions from the Gateway/App.
A
account is required to use the
App, complete the activation process at:
http://tevolve.termoweb.net
If the towel rail has been linked to the Gateway
and for some reason communication is lost, the
Link icon disappears and the antenna starts
flashing in red alternating with Link text.
KEYPAD LOCKING (ANTI-TAMPER)
The keypad can be locked
to prevent any unauthorised
person (children, people
in public places, nurseries,
offices, hotels etc.) altering
the settings of the towel rail.
A Password is required
to lock the keypad (0 0 0 0
by default), See Password
Settings
Chapter
for
further details on changing
passwords.
To Lock the towel rail
Press and hold the + and –
buttons until the lock screen
appears. 40. Enter
the
password on the screen
using +/- buttons followed by
Mode/OK
.
The screen will change to show the Lock screen
and any button presses will be ignored and the
locked screen displayed.
To unlock the keypad press and hold the +
and - until the unlock screen appears. Enter the
password using the +/- buttons and then press
Mode/OK
. If the incorrect password is entered
“INVALID CODE” will be displayed.
When the keypad is locked the towel rail will
still receive communications from the Gateway.
ADVANCED SETTINGS
The Advanced settings
menu is password protected
to prevent any inadvertent
changes to the factory
settings.
To access the Advanced
settings, enter the password (default 0 0 0 0).
It is strongly recommended to set a custom
password once installation is complete. (For more
information see the password section).
The units menu allows the
main temperature units of
the towel rail to be chosen
between Celsius (°C) and
Fahrenheit (°F). Change
using +/- buttons and confirm
with
Mode/OK
.
The Control Type menu
allows five types of control
of the temperature control
setting. PID will calculate
the best switching point for
the heater depending on
previous room readings.
Hysteresis is the difference between the detected
temperature and the set-point required before the
heater will come on. It is not recommended to
change these settings. To change the control type
use +/- buttons to select an option and confirm
with
Mode/OK
.
The temperature offset
menu allows the display
temperature to be adjusted
by ± 3°C. Adjusting this set-
point will affect the operation
of the thermostat set-points,
changing this setting is only recommended if the
displayed temperature is noticeably different from
another sensor in the space. To adjust the offset
in 0.1’C increments use +/- buttons and confirm
with
Mode/OK
.