background image

8

Wednesday

11:00

21

.5°C

Wed. 11:00

Set point:

COMFORT

Wed. 11:00h

21

.5°C

Set point:

COMFORT

21

.0°C

Set point:

OK

ECO

18

.0°C

Set point:

OK

ANTI-FROST

7

.0°C

Set point:

OK

21

.5°C

Wed. 11:00

Set point:

COMFORT

CONFIG

COMFORT
ECO
ANTI-FROST
PROGRAM
SETTINGS

COMFORT

TIME
DATE
DST

TIME SETTINGS

CONFIG

COMFORT
ECO
ANTI-FROST
PROGRAM

SETTINGS

COMFORT

TIME

Settings
DISPLAY

Settings
ADVANCED

Settings

SETTINGS

USING IN OPERATING MODES 

To assist with programming the TFT screen is 

backlit and will stay illuminated for approximately 

10  seconds  after  the  last  button  is  pressed.  (To 

change  the  backlight  time,  see  the  section  on 

DISPLAY)

When the towel rail is operational and the room 

temperature is lower than the set temperature the 

heating  symbol    will  be  shown  indicating  that 

the towel rail is producing heat. 

The  following  screens  show 

MANUAL

AUTO

 

and 

OFF

 modes. To scroll between 

MANUAL

 and 

AUTO

 press

 Mode/OK

 button. 

To enter and exit 

OFF

 mode press the 

ON/OFF 

button. When 

OFF

 mode is exited, it return to the 

mode used prior to entering 

OFF

 mode.

When  the  towel  rail  is  in 

MANUAL

  mode  the 

temperature can be adjusted by pressing the +/- 

button. The towel rail will regulate the room to the 

chosen set temperature.

When  the  towel  rail  is  in 

AUTO

  mode  the 

temperature can be adjusted by pressing the +/- 

buttons. This change will remain active until either 

the next programme change or until midnight when 

the temperature will revert to the preset value.

When  the  temperature  has  been  adjusted  in 

AUTO mode a hand will show beside the auto to 

symbol to show the amended set-point. 

To  return  to AUTO  mode  press  the

 Mode/OK 

button.

NOTE:

 To rapidly change the temperature set-

point in any mode press and hold the +/- keys.

SET AUTO TEMPERATURES 

To amend the temperature set points used in the 

AUTO mode, press and hold the CONFIG button 

until the following screen appears:

Select either Comfort, Eco or Anti-Frost by using 

the  +/-  button  and  press 

Mode/OK

  to  enter  the 

menu.

Press the +/- button to change the temperature 

of  each  mode  then  press 

Mode/OK

  to  confirm 

and return to the main operation screen, repeat 

the above to set the other program temperature 

set-points.

SETTING THE TIME AND DATE 

If a towel rail is paired with a Gateway then the 

local time from the internet is automatically applied 

to the towel rail.

To set the Clock on an unpaired Towel rail, press 

and  hold  the  CONFIG  button  until  the  CONFIG 

menu is shown and then select SETTINGS using 

the  +/-  button,  press 

Mode/OK

  and  then  select 

TIME  Settings  using  the  +/-  button  and  press 

Mode/OK

 again.

In  the  TIME  menu  the 

Time,  Date  and  Daylight 

Savings  (DST)  can  be  set. 

These  can  be  selected  by 

pressing the +/- button.

Summary of Contents for Colorado DGi+ 450

Page 1: ...E1400298 20210204 NOTE A qualified electrician must carry out the electrical installation of this towel rail The electrical installation must comply with current UK regulations Any claim on the warra...

Page 2: ...in operating modes 8 Set auto temperatures 8 Setting the time and date 8 Entering a program 9 Boost 10 Display settings 10 Programming with APP 11 Keypad Locking Anti Tamper 11 Advanced settings 11 Pa...

Page 3: ...mended to install this towel heater so that the lowest heating bar is at least 600 mm above the floor This appliance must only be connected according to the rules and standards in application by an au...

Page 4: ...Scan this QR code to access to the download It is also possible to programme each towel rail individually without theApp by using the built in controls and screen This may be convenient for single hea...

Page 5: ...tches and other control devices can be touched by a person in the bathtub or shower This product is rated as IP44 and can be located in zone 2 the area stretching 60cm outside the perimeter of the bat...

Page 6: ...etween the 2nd and 3rd horizontal tubes from the bottom STEP 1 First the 4 supports are placed on the towel rail take a piece B fix the piece D with the screw C and insert it between two tubes from th...

Page 7: ...tivate the function required Switching ON Once the towel rail has been mounted on the wall and correctly connected to the mains electricity power supply press the main On Off button on the left side o...

Page 8: ...rail is in AUTO mode the temperature can be adjusted by pressing the buttons This change will remain active until either the next programme change or until midnight when the temperature will revert to...

Page 9: ...ram into the towel rail first select the day of the week in the upper left corner of the programming screen by using the button and press Mode OK change the day to the day you want to program using bu...

Page 10: ...tween 1 hour and 24 hours using the buttons To return to the BOOST screen press the CONFIG button You can quickly adjust the duration with the BOOST button Each press will increase the duration of BOO...

Page 11: ...Settings Chapter for further details on changing passwords To Lock the towel rail Press and hold the and buttons until the lock screen appears 40 Enter the password on the screen using buttons followe...

Page 12: ...at the programmed starting time To turn on off use the buttons and confirm with Mode OK The Low Surface Temperature LST menu will allow the output of the heater to be limited to a lower setting to pre...

Page 13: ...comes with a Runback mode for use when the heater will be installed in areas where restricted user control is required When Runback Mode is active it allows the user to set the towel rail to run for...

Page 14: ...heater is installed can fall to outside of the Runback operation This temperature can be set between 7 C minimum and 0 5 C less than the Runback temperature set point When Setback is operational the s...

Page 15: ...heating system is not accessible from the app However the running schedule remains in the towel rail memory and continues with the last user setting so long as the lithium battery is not flat The Lit...

Page 16: ...t mode temperature 21 C Boost mode time 1 hour Low Surface Temperature Disabled Password status Activated Password 0000 Units C Keyboard Unlocked Easy mode Disabled Runback mode Disabled Setback Disab...

Page 17: ...elmax 0 0005 kW 0 0005 kW At minimum heat output elmin 0 0005 kW 0 0005 kW In standby mode elSB 0 0005 kW 0 0005 kW Type of heat output room temperature control Electronic room temperature control pl...

Page 18: ...18 NOTES...

Page 19: ...19 NOTES...

Page 20: ...posed of with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types o...