Section 5: Programming
OFF: does not activate when any module tamper condition occurs.
10 – Zone Tampers
ON: activates when any zone tamper condition occurs.
OFF: does not activate when zone tamper conditions occur.
161 – DC Trouble
01 – True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
02 – PGM Timer
ON: output remains active until an access code is entered or certain criteria have been met, depending on the PGM
type.
OFF: output remains active until the PGM output timer expires.
09 – Battery Low
ON: activates when a low battery trouble occurs.
OFF: does not activate when a low battery trouble occurs.
10 – Battery Absent
ON: activates when a battery absent trouble occurs.
OFF: does not activate when a battery absent trouble occurs.
165 – Prox Used
01 – True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
175 – Bell Prog Access
01 – True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
176 – Remote Operation
01 – True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
184 – Open After Alarm
01 – True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
200 - Zone Follower - Single Zone
01 – True Output/Inverted
ON: deactivated during normal operation, activated when triggered.
OFF: activated during normal operation, deactivated when triggered.
02 – Timed Output
ON: output remains active until the PGM output timer expires.
OFF: output remains active until the zone is restored.
201 – 216 Zone Follower Zones 1-128
01 – True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
- 84 -