Appendix 3: Template Programming Tables
Enable All User Open/Close Reports
[308][201] - Bit 1 User Closing - On
[308][201] - Bit 2 User Opening - On
[308][201] - Bit 5 Special Closing - On
[308][201] - Bit 6 Special Opening - On
[308][202] - Bit 1 Automatic Closing - On
[308][202] - Bit 2 Automatic Opening - On
[308][202] - Bit 3 Automatic Cancel - On
l
Zone Alarm Restore Group - Disables all zone alarm restore reporting codes
Zone Alarm Restore Group
DLS/Installer Lead In/Out Programming
Restore zone alarm reporting codes
[307][001] - Bit 2 Alarm Restore - Off
[307][002] - Bit 2 Alarm Restore - Off
[307][003] - Bit 2 Alarm Restore - Off
[307][004] - Bit 2 Alarm Restore - Off
[307][005] - Bit 2 Alarm Restore - Off
[307][006] - Bit 2 Alarm Restore - Off
[307][007] - Bit 2 Alarm Restore - Off
[307][008] - Bit 2 Alarm Restore - Off
[307][009] - [128] Bit 2 Alarm Restore - Off
l
Installer Lead-in/Lead-out and DLS Lead-in/Lead-out
DLS/Installer Lead In/Out Group
DLS/Installer Lead In/Out Programming
DLS/Installer Disabled
[308][312] - Bit 1 Installer Lead In - Off
[308][312] - Bit 2 Installer Lead Out - Off
[308][312] - Bit 3 DLS Lead In - Off
[308][312] - Bit 4 DLS Lead Out - Off
[308][312] - Bit 5 SA Lead In - Off
[308][312] - Bit 6 SA Lead Out - Off
Digit 5 DLS Connection Options
Option
Programming Section
DLS Connection/Call Back Setting
1
[401] Option 1 OFF
Option 3 OFF
Option 4 OFF
[406] 000
Double Call Disabled
Call Back Disabled
User Initiated Call Up Disabled
Number of Rings to Answer On Disabled
2
[401] Option 1 ON
Option 3 OFF
Option 4 OFF
[406] 008
Double Call Enabled
Call Back Disabled
User Initiated Call Up Disabled
Number of Rings to Answer On is 8
3
[401] Option 1 ON
Option 3 ON
Option 4 OFF
[406] 008
Double Call Enabled
Call Back Enabled
User Initiated Call Up Disabled
Number of Rings to Answer On is 8