Appendix 1: Reporting Codes
Section #
Definition
Dialer Dir-
ection*
Automatic Contact ID
Codes
SIA Auto Rep Codes**
[308]-[355]
Alternate Communicator Receiver 2 Supervisory trouble/restore
MA/R
E(3)5A-002/R(3)5A-002
YS-0002 / YK-0002
[308]-[355]
Alternate Communicator Receiver 3 Supervisory trouble/restore
MA/R
E(3)5A-003/R(3)5A-003
YS-0003 / YK-0003
[308]-[355]
Alternate Communicator Receiver 4 Supervisory trouble/restore
MA/R
E(3)5A-004/R(3)5A-004
YS-0004 / YK-0004
[308]-[353]
Alternate Communicator SMS Config trouble/restore
MA/R
E(3)AA-001
R(3)AA-001
YX-0001 / YZ-0001
[308]-[351]
Remote Programming Begin/End
MA/R
E(6)27-000 / E(6)28-000
LB-0000 / LS-0000
Wireless Events
[308]-[361]
Wireless Zone Low Battery trouble/restore. ZZZ= Wireless
zones 001-128.
MA/R
E(3) 84-ZZZ
R(3) 84-ZZZ
XT-ZZZZ / XR-ZZZZ
[308]-[361]
Wireless Device Low Battery trouble/restore. ZZZ= 601-616:
wireless keypads, 701-732: wireless keys, 801-816: wireless
Sirens, 901-908: wireless repeaters
MA/R
E(3) 84-ZZZ
R(3) 84-ZZZ
XT-ZZZZ / XR-ZZZZ
[308]-[361]
Wireless Zone AC trouble/restore
MA/R
E(3)A1-ZZZ
R(3)A1-ZZZ
AT-ZZZZ / AR-ZZZZ
[308]-[361]
Wireless Device Fault/restore
MA/R
E(3)8A-ZZZ
R(3)8A-ZZZ
UT-ZZZZ / UJ-ZZZZ
[308]-[361]
Wireless Temperature and Flood Probe trouble/restore
MA/R
E(3)8A-ZZZ
R(3)8A-ZZZ
KT-ZZZZ / KJ-ZZZZ
[308]-[361]
Repeater 1 AC fail/restore
MA/R
E (3)A1-901
R (3)A1-901
AT-0901 / AR-0901
[308]-[361]
Repeater 2 AC fail/restore
MA/R
E(3)A1-902
R (3)A1-902
AT-0902 / AR-0902
[308]-[361]
Repeater 3 AC fail/restore
MA/R
E (3)A1-903
R (3)A1-903
AT-0903 / AR-0903
[308]-[361]
Repeater 4 AC fail/restore
MA/R
E (3)A1-904
R (3)A1-904
AT-0904 / AR-0904
[308]-[361]
Repeater 5 AC fail/restore
MA/R
E(3)A1-905
R (3)A1-905
AT-0905 / AR-0905
[308]-[361]
Repeater 6 AC fail/restore
MA/R
E (3)A1-906
R (3)A1-906
AT-0906 / AR-0906
[308]-[361]
Repeater 7 AC fail/restore
MA/R
E (3)A1-907
R (3)A1-907
AT-0907 / AR-0907
[308]-[361]
Repeater 8 AC fail/restore
MA/R
E (3)A1-908
R (3)A1-908
AT-0908/ AR-0908
[308]-[361]
Self Test Trouble/Restore*
Note: To prevent a reporting code conflict do not program
PG9984 as zone 1.
MA/R
E (3)89-ZZZ
R (3)89-ZZZ
YX/YZ-ZZZZ
Miscellaneous Alarms
[308]-[001]
Duress Alarm - Code entered at keypad
A/R
E(1)21-000
HA-0000
[308]-[001]
Opening After Alarm - Disarmed with alarm in memory
A/R
E(4)58-000
OR-0000
[308]-[001]
Recent Closing - Alarm occurs within two minutes of system
arming
A/R
E(4)59-UUU
CR-UUUU
[308]-[001]
Burglary Verified
A/R
E(1)39-000
BV-0000
[308]-[001]
Burglary Not Verified
A/R
E(3)78-000
BG-0000
[308]-[001]
HSM2108 Zone Expander Supervisory Alarm/restore
A/R
E(1)43-000
R(1)43-000
UA-0000 / UH-0000
[308]-[002]
Holdup Verified
A/R
E(1)29-000
HV-0000