Section 5: Programming
5.3.18 Wireless Programming
[804] Wireless Programming
This programming section is used to enroll, program and delete wireless devices. Note that the HSM2HOSTx wireless trans-
ceiver or RF model keypad must be installed in order to enroll wireless devices.
[000] – Wireless Device Enrollment
To enroll a wireless device using this method, press and hold the Enroll button on the device for 2-5 seconds until the LED
illuminates then release the button. The alarm system automatically discovers the device and the keypad displays a con-
firmation message. The device ID, type and the next available zone number are displayed. Press [*] to accept or scroll to
another available zone number. Batteries must be installed in the wireless device in order to enroll.
Note:
Ensure wireless signal strength is adequate before mounting the wireless device. See the instructions provided with
the wireless device for details.
Note:
For complete wireless device programming descriptions and worksheets, see the HSM2Hostx wireless transceiver
installation manual.
[850] Cellular Signal Strength
This section is used to view both the cellular signal strength and the radio technology in use.
Table 5-3 : Cellular Technology
Display
Technology
GP
GPRS
ED
EDGE
HS
HSPA
H+
HSPA
CD
CDMA
EV
EVDO
5 bars indicate maximum signal strength. 0 bars indicate the communicator is not connected to the network.
[851] Alternate Communicator Programming
See the alternate communicator installation manual for programming instructions.
[860] Display Keypad Slot Number
The 2-digit slot number of the keypad being used is displayed in this read only section.
[861]-[876] Keypad Programming
Use section [861] to [876] to configure keypads 1 to 16. For information on keypad programming, refer to the installation
sheet supplied with the keypad.
EN
Note:
For EN50131 compliant installations [861][021] options 1 and 2 must be disabled.
[899] Template Programming
Template programming allows quick programming of the minimum functions required for basic operation. This section is
used to view current template programming options and to define certain system parameters. Press the (#) key to accept the
displayed value and advance to the next option. The following options are available:
l
5-digit Template Code: Displays the current 5-digit template programming code (default: 00000). Each digit in the
code selects a set of pre-defined programming options, as described below:
l
Digit 1 - zone 1-8 definition options
l
Digit 2 - system EOL options
l
Digit 3 - alarm controller communications options
l
Digit 4 - reporting code configurations
l
Digit 5 - DLS connection options
l
Central Station Telephone Number: The phone number used to contact the central monitoring station (32 character
limit).
- 116 -