Appendix 1: Reporting Codes
Section #
Definition
Dialer Dir-
ection*
Automatic Contact ID
Codes
SIA Auto Rep Codes**
[308]-[101]
HSM2208: 8-Output Expander module #12 tamper/restored
T/R
E(3)41-212 / R(3)41-212
ES-0212 / EJ-0212
[308]-[101]
HSM2208: 8-Output Expander module #13 tamper/restored
T/R
E(3)41-213 / R(3)41-213
ES-0213 / EJ-0213
[308]-[101]
HSM2208: 8-Output Expander module #14 tamper/restored
T/R
E(3)41-214 / R(3)41-214
ES-0214 / EJ-0214
[308]-[101]
HSM2208: 8-Output Expander module #15 tamper/restored
T/R
E(3)41-215 / R(3)41-215
ES-0215 / EJ-0215
[308]-[101]
HSM2208: 8-Output Expander module #16 tamper/restored
T/R
E(3)41-216 / R(3)41-216
ES-0216 / EJ-0216
[308]-[101]
HSM2204: Power Supply-1A (4 high-current outputs) #1 tamper-
/restored
T/R
E(3)41-601 / R(3)41-601
ES-0601 / EJ-0601
[308]-[101]
HSM2204: Power Supply-1A (4 high-current outputs) #2 tamper-
/restored
T/R
E(3)41-602 / R(3)41-602
ES-0602 / EJ-0602
[308]-[101]
HSM2204: Power Supply-1A (4 high-current outputs) #3 tamper-
/restored
T/R
E(3)41-603 / R(3)41-603
ES-0603 / EJ-0603
[308]-[101]
HSM2204: Power Supply-1A (4 high-current outputs) #4 tamper-
/restored
T/R
E(3)41-604 / R(3)41-604
ES-0604 / EJ-0604
[308]-[101]
HSM2300: Power Supply module #1 tamper/restored
T/R
E(3)41-621 / R(3)41-621
ES-0621 / EJ-0621
[308]-[101]
HSM2300: Power Supply module #2 tamper/restored
T/R
E(3)41-622 / R(3)41-622
ES-0622 / EJ-0622
[308]-[101]
HSM2300: Power Supply module #3 tamper/restored
T/R
E(3)41-623 / R(3)41-623
ES-0623 / EJ-0623
[308]-[101]
HSM2300: Power Supply module #4 tamper/restored
T/R
E(3)41-624 / R(3)41-624
ES-0624 / EJ-0624
[308]-[101]
HSM2955: Audio module tamper/restore
T/R
E(3)41-553 / R(3)41-553
ES-0553 / EJ-0553
[308]-[101]
Alternate Communicator Tamper (only on supported models)
T/R
E(3)41-950 / R(3)41-950
ES-0950 / EJ-0950
[308]-[101]
Keypad Lockout - Incorrect access code entry
T/R
E(4)61-000 / R(4)61-000
JA-0000
Opening Events
[308]-[201]
User Openings - Disarmed by user
O/C
E(4)A1-UUU
OP-UUUU
[308]-[202]
Automatic Arming Canceled
O/C
E(4)64-UUU
CI-0000
[308]-[201]
Special Opening - System disarmed using: keyswitch, main-
tenance code, DLS software, wireless key
O/C
E(4)AA-000
OP-0000
[308]-[211]
Late to Open - System not disarmed before late to open time
expired
O/C
E(4)53-000
CT-0000
[308]-[202]
Automatic (Schedule) Opening
O/C
E(4)A3-000
OA-0000
[308]-[201]
Keyswitch Open
O/C
E(4)A9-ZZZ
OS-ZZZZ
Closing Events
[308]-[201]
User Closings - System armed by user, wireless key
O/C
R(4)A1-UUU
CL-UUUU
[308]-[221]
Partial Closing - 1 or more zones bypassed when armed
O/C
E(4)56-000
CG-0000
[308]-[201]
Special Closing - System armed via: quick arm, keyswitch, func-
tion key, maintenance code, DLS software
O/C
R(4)AA-000
CL-0000
[308]-[211]
Late to Close - Auto-arm prealert sounded
O/C
E(4)54-000
CI-0000
[308]-[211]
Exit Fault
O/C
E(3)74-ZZZ
EA-ZZZZ
[308]-[202]
Automatic (Schedule) Closing
O/C
R (4)A3-000
CA-0000
[308]-[201]
Keyswitch Close
O/C
R(4)A9-ZZZ
CS-ZZZZ
System Trouble Events
[308]-[301]
Battery trouble/restore - Main panel
MA/R
E(3)A2-000 / R(3)A2-000
YT-0000 / YR-0000
[308]-[301]
Battery absent trouble/restore - Main panel
MA/R
E(3)11-000 / R(3)11-000
YM-0000 / YR-0000
[308]-[301]
Panel AC trouble/restore - Main panel
MA/R
E(3)A1-000 / R(3)A1-000
AT-0000 / AR-0000
[308]-[302]
Bell Circuit trouble/restore
MA/R
E(3)21-000 / R(3)21-000
YA-9999 / YH-9999
[308]-[302]
TLM (telephone line) fail/restore
MA/R
E(3)51-000 / R(3) 51-000
LT-0001 / LR-0001
[308]-[302]
Auxiliary Power trouble/restore
MA/R
E(3) 12-000 / R(3) 12-000
YP-0000 / YQ-0000
- 194 -
Summary of Contents for Neo
Page 6: ......
Page 14: ...Section 2 Installation Figure 2 1 Wiring Routing North America only 14 ...