
Appendix 1: Reporting Codes
Section #
Definition
Dialer Dir-
ection*
Automatic Contact ID
Codes
SIA Auto Rep Codes**
[308]-[011]
Alarm Canceled before expiry of alarm cancellation timer
A/R
E(4)A6-UUU
OC-UUUU
[308]-[011]
PGM2 (Silent 24 Hour Input) -Aux Input Alarm/restore
A/R
E(1)46-992
R(1)46-992
UA-0992 / UH-0992
[308]-[011]
PGM2 (Audible 24 Hour Input) -Aux Input Alarm/restore
A/R
E(1)4A-992
R(1)4A-992
UA-0992 / UH-0992
[308]-[305]
PGM2 2-Wire Smoke Alarm/Restore
A/R
E(1)11-992
R(1)11-992
FA-0992 / FH-0992
Priority Alarm and Restoral Events
[F] Key alarm/restore
A/R
E(1)1A-000
R(1)1A-000
FA-0000 / FH-0000
[M] Key alarm/restore
A/R
E(1)AA-000
R(1)AA-000
MA-0000 / MH-0000
[P] Key alarm/restore
A/R
E(1)2A-000
R(1)2A-000
PA-0000 / PH-0000
Miscellaneous Closing
[308]-[221]
Zone Bypass at time of arming
O/C
E(5)7A-ZZZ
UB-ZZZZ
[308]-[221]
Zone Unbypass
O/C
R(5)7A-ZZZ
UU-ZZZZ
Testing
[308]-[401]
Walk Test Begin/End
T
E(6)A7-UUU
R(6)A7-UUU
TS-UUUU/TE-UUUU
[308]-[401]
Periodic Test
T
E(6)A2-000
RP-0000 / RY-0000
[308]-[401]
Periodic Test with Trouble
T
E(6)A8-000
RY-0000
[308]-[401]
System Test - [*][6] bell/communications test
T
E(6)A1-000
RX-0000
Maintenance
[308]-[311]
General System trouble/restore - An RF jam trouble
occurred/was restored
MA/R
E(3) AA-000
R(3) AA-000
YX-0000 / YZ-0000
[308]-[311]
Fire trouble/restore
MA/R
E(3)73-000
R(3)73-000
FT-0000 / FJ-0000
[308]-[314]
Gas trouble/restore
MA/R
E(3)8A-ZZZ
R(3)8A-ZZZ
GT-ZZZZ / GJ-ZZZZ
[308]-[314]
Heat trouble/restore
MA/R
E(3)8A-ZZZ
R(3)8A-ZZZ
KT-ZZZZ / KJ-ZZZZ
[308]-[314]
Freeze Trouble / Restore
MA/R
E(3)8A - ZZZ
R(3)8A - ZZZ
ZT-ZZZZ / ZJ-ZZZZ
Carbon Monoxide Trouble
MA/R
E(3)8A - ZZZ
R(3)8A - ZZZ
UT-ZZZZ / UJ-ZZZZ
[308]-[311]
Cold Start - System has restarted after total power loss
MA/R
R(3) A5-000
RR-0000
[308]-[312]
Event Buffer 75% Full
MA/R
E(6)22-000
JL-0000
[308]-[312]
DLS Lead In - Download session start
MA/R
E(4)11-000
RB-0000
[308]-[312]
DLS Lead Out - Download session stop
MA/R
E(4)12-000
RS-0000
[308]-[312]
SA Lead In - Download session start
MA/R
E(4)11-000
RB-0000
[308]-[312]
SA Lead Out - Download session stop
MA/R
E(4)12-000
RS-0000
[308]-[312]
Installer Lead In - Installer Programming has been entered
MA/R
E(6)27-000
LB-0000
[308]-[312]
Installer Lead out - Installer Programming has been exited
MA/R
E(6)28-000
LS-0000
[308]-[313]
Panel firmware update begin/ successful
MA/R
E(9)01-900
R(9)01-900
LB-0900 / LS-0900
- 198 -
Summary of Contents for Neo
Page 6: ......
Page 14: ...Section 2 Installation Figure 2 1 Wiring Routing North America only 14 ...
Page 235: ......