Section 6: Programming Worksheets
o
Receiver #2
o
Receiver #4
[318] Partition 8 Call Directions
001 – Partition 8 Alarm/ Restore:
R
Receiver #1
o
Receiver #3
o
Receiver #2
o
Receiver #4
002 – Partition 8 Tamper/ Restore:
R
Receiver #1
o
Receiver #3
o
Receiver #2
o
Receiver #4
003 – Partition 8 Opening/ Closing:
o
Receiver #1
o
Receiver #3
o
Receiver #2
o
Receiver #4
[350] Communicator Formats
Description on page 107
(2-Digit decimal)
001 – Receiver 1:
003 – Receiver 3:
Range: 03= Contact ID, 04= SIA (Default)
002 – Receiver 2:
004 – Receiver 4:
[377] Communication Variables
(3-digit decimal)
Range: 000-255 attempts unless otherwise noted
Description on page 107
001 – Swinger Shutdown Attempts:
Alarms and Restore (000-014):
Default: 003
Tampers and Restore:
(
CP-01
Default: 002)
Maintenance and Restore:
002 – Communication Delays:
Communication Zone Delay (Default: 000
CP-01
Default: 030):
AC Failure Communication Delay (Default:030
minutes/Hours):
TLM Trouble
Delay (
NA
Default:010
checks
EN
Default:002 checks):
Wireless Zone Low Bat. Transmission Delay (Default: 007
days):
Delinquency Transmission Cycle Delay (Default: 030
days/hours):
Communications Cancel Window (Default: 000 minutes
CP-01
Default: 005 minutes):
003 – Periodic Test Transmission Cycle (Default: 030 hours/days):
004 – Periodic Test Transmission Time of Day (Default: 9999):
011 – Maximum Dialing Attempts: (Default: 005):
012 – Delay Between PSTN Attempts: (Default: 003 seconds):
013 – Delay Between Force Attempts: (Default: 020 seconds):
014 – Post Dial Wait for Handshake: (Range: 001-255; Default: 040 Seconds; UL=45):
015 – IP/GS Wait for Ack: (Range: 001-255; Default: 060 seconds):
016 – IP/Cellular Fault Check Timer: (Range: 003-255; Default: 010):
[380] Communicator Option 1