Section 4: System Operation
7 – Bell Squawk
When this option is assigned, the main bell squawks when the alarm system is away armed. For example, use the arm/dis-
arm bell squawk attribute to have wireless key access codes squawk the bell, while other codes are silent. To do this, enable
this attribute on all access codes associated with wireless keys. This option is off by default for all access codes.
Note:
One squawk indicates arming completed; two squawks indicates disarming completed.
Note:
This feature is independent of the system option “Bell Squawk on Away Arming.” See "[017] System Option 5" on page
The master code's attributes cannot be changed from default. The bell squawk is off at default.
8 – One Time Use Code
Converts standard user code into one time use code. See " " on page 47 for details. Do not apply this code to users with wire-
less keys assigned.
Using an LCD keypad:
1. Press [*][5][Master Code].
2. Use the scroll keys to choose a user (02-95) then press [*] to select.
3. Scroll to “Press [*] for User Options” then press [*] to select.
4. Scroll to a user attribute and press [*] to toggle it on or off.
Using an LED/ICON keypad:
1. Press [*][5][Master Code].
2. Key in the 2-digit number of the access code to edit. [5] for attribute programming.
3. Press the keypad number key corresponding to an attribute to toggle it on or off.
Add User Labels
Custom labels can be programmed for each user to more easily identify them on the alarm system. Labels can be a max-
imum of 16 characters.
Using an LCD keypad:
1. Press [*][5] then select a user (02-95).
2. On the “Press [*] for User Labels” screen, press [*].
3. Key in the custom user label. For instructions on how to input labels, See "Adding Labels" on page 61
Assigning Proximity Tags
This section is used to assign proximity tags to users.
Note:
A proximity tag cannot be assigned to the master code.
Using an LCD keypad:
1. In the [*][5] menu, select a user or enter a user number.
2. Select “Press [*] for Prox Tag”, then pass the enrolled tag near the tag reader on the keypad. A proximity tag can only be
assigned to one user at a time. Invalid (un-enrolled) proximity tags cannot be used.
To delete a proximity tag:
1. Select a user and then select Press [*] for Prox Tag.
2. Press the [*] key when prompted to delete the proximity tag.
Using an LED/ICON keypad:
1. Press [*][5][Master/Supervisor Code].
2. Key in a 2-digit user code.
3. Key in [2].
4. Pass the enrolled tag near the tag reader on the keypad.