Section 5: Programming
Settle Delay:
This timer enables a programmable, short duration bypass of all zones on the partition at the time of arming. It allows motion
detectors to restore when the system is armed to help prevent false alarms.
The typical value for this timer is 5 seconds, but can be increased if false alarms persist. Program 000 for no settle delay.
The settle delay duration is programmed in seconds. Valid entries are 000 to 010 seconds.
[900] – Bell Delay Partition Mask
This option enables or disables the Bell Delay feature for individual partitions. When the option is enabled, Bell Delay is
applied to the selected partition during alarm conditions. When the option is disabled, Bell Delay is not applied. The default
setting is (Y): enabled.
[901]/[902] – Daylight Savings Begin/End
Daylight Begin [001] and Daylight End [002]:
Set the date and time daylight savings starts and ends.
Month
Valid entries are 001-012 (January to December).
Week
Valid entries are 000-005.
Enter “000” to program a specific date (1-31) in the Day field. Enter 001-005 to program the specific week of the month. 005
is the last week of the month.
Day
1-31 (if 000 is programmed in the Week field). 0-6 (Saturday-Sunday) if 001-005 is programmed in the Week field.
Hour
Valid entries are 00-23 hours. This is the time of day to advance or turn the clock back.
Increment
Valid entries are 1 or 2 hours. This is the number of hours to advance or turn the clock back.
5.3.4 Access Codes
This section is used by installers to program the installer code, the master code and the maintenance code. For information
on programming other access codes, see "[*][5] Program Access Codes" on page 47.
[006] Installer Defined Access Codes
This is the base menu used by installers to program the installer code [001], the master code [002] and the maintenance
code [003]. See below for details.
[001] – Installer Code
This code is used by the installer to gain access to Installer Programming [*][8]. Users with this access code have access to
all levels of system programming.
EN
Note:
For EN50131-1 approved installations the installer code cannot change the master code or any other level 3 codes.
[002] – Master Code
This code is used by the master user, a person designated to perform operational tasks beyond those of the standard user.
The master code provides access to functionality in the [*][5] and [*][6] menus.
[003] – Maintenance Code
This code is usually assigned temporarily to maintenance personnel who must deactivate the alarm to enter the premises.
The maintenance code can arm and disarm the system, but does not grant access to any other functionality.