The following diagram shows how to network a TFT500 Omni Driver inside an elevator car:
Unscreened Twisted Pair
for network
2× AWG14 cables
for 24V power and data
CAT5
for network (max length 300 feet)
HDMI
(HDCP encryption not supported)
110V - 230V Mains power cable
12V DC
PSU
TFT Screen
with DVI Input
TFT500
DragonFly
Omni Driver
110-230V
AC Input
Elevator Car
Machine Room
110-230V
AC Input
}
Inputs from
Elevator Controller
2 Wires for
Power and Data
IND055
Controller
Interface
24V DC
PSU
110-230V
AC Input
110-230V
AC Input
Ethernet
Extender
4 × UTP on Trailer
Max length 300 feet, or 2500 feet if
Ethernet Extenders are used
CAT5
Building Management Room
CAT5 Ethernet connections
to other machine rooms
CAT5
Ethernet
Extender
110-230V
AC Input
Ethernet
Switch
PC / Laptop