20
Crane 2000LE and 3000LE
05-2021
DL6001-003
Crane 2000LE and 3000LE Wiring, Setup and Troubleshooting
In-ground Motion Assist 360 drive with Remote Control Enclosure
Chapter 6
Fig. 6.7.2 Remote enclosure ground wire connections
6.7 Install Motion Assist control unit assembly into enclosure
Fig. 6.7.1 Control unit installation in remote enclosure
Detail
“F”
Detail
“E”
Ground wire to Motion Assist 360 power supply
Ground wire to Motion Assist 360 power supply
2
10,11
10,11
7
3,4,5
TIPS AND RECOMMENDATIONS
Control unit bracket will be
installed using enclosure internal
panel mounting studs.
6.7.1 Install Motion Assist 360 control unit
assembly into enclosure.
1. Remove nuts from enclosure internal
panel studs.
2. Install control unit bracket onto two
enclosure studs.
3. Reinstall the two enclosure nuts and
tighten.
6.7.2 Connect ground wire from power
supply to control unit.
1. Connect ground wire from power supply
to control unit SHCS.
• Reference Fig. 6.7.3, Detail "D"
6.7.3 Connect ground wire from power
supply to enclosure ground stud.
1. Remove nut from enclosure ground stud
and install ground wire from Motion
Assist 360 power supply to enclosure
ground stud (Fig. 6.7.4).
6.7.4 Connect ground wire from enclosure
door to enclosure ground stud.
1. Remove nut (12) from door ground stud
(Fig. 6.7.3).
2. Install ground wire ring lug on stud.
3. Reinstall enclosure ground stud nut (13),
Fig. 6.7.4).
1
Motion Assist 360
power supply
7
Bracket
DC6057
13
5/16 x 1/2" SHCS,
SS DF6018-01G
4
5/16"" flat washer,
DF6019-01G
5
External
tooth
lock
washer DF6016-01G
9
Earth
grounding
cable DX6009
1
0
Enclosure internal
panel stud
11
Enclosure panel stud
nut
Fig. 6.7.3
Detail "E"
9
12
Fig. 6.7.4
Detail "F"
Ground wire from
door ground stud
Ground wires to power supply
13