12.4 Motion Assist 360 power up
Fig. 12.4.4 Power up display
5
System
check
6
Self
check
7
Horizontal
dashes
move up and down
Fig. 12.4.5 Device ID, firmware
version display example
5
6
7
> 3s Reset
< 3s Quit
LEARN
< 3s
> 3s
Fact-Setup
PRG
> 3s
> 8s
1
2
Fig. 12.4.7 Keypad / 2 digit display
1
Keypad
2
2 digit display
Step Action
1.
Turn Mode switch to "0"
(Off)
.
2.
Press Emergency Stop pushbutton.
• At the door entrance or exit.
3.
Check wings for bookfold.
• Check that all wing deflection contacts are
closed (no wings are folded).
4.
Rotate wings to Home position.
• Wing locks are in line with floor strikes.
5.
Turn on customer 115 Vac power to
Motion Assist 360 drive power supply.
WARNING
After power on,
"S" Motion Assist module
green light must be slowly flashing off and
on.
.1
• System check; series of letters and numbers
rapidly displayed (
5
).
• Control unit self check; two segments jumping
back and forth (
6
).
• Horizontal dashes move up and down (
7
).
.2
Display and keypad orientation.
• While 2 digit display segments move up and
down (
7
), use
or
buttons to select
display and keypad orientation.
TIPS AND RECOMMENDATIONS
Display and keypad operation inverted.
Display and keypad operation unchanged.
.3
Device ID and firmware display.
• After display and keypad orientation (Step 5.2)
device ID and firmware version will scroll across
display (Fig. 12.4.5).
•
Device ID _________
• Firmware
version
(format F x x x x)
.4
Program mode is displayed (Fig. 12.4.6).
6.
Set basic parameters F, d and dE, go to Para. 12.5
Fig. 12.4.2 Emergency Stop pushbutton
Fig. 12.4.3 Motion Assist 360
power supply
1
Power
supply
2
Plug, customer 115
Vac power
Fig. 12.4.6 Program mode
12.4.1 Motion Assist 360 power on procedure.
Fig. 12.4.1 Mode switch off
1