40
Crane 2000LE and 3000LE
05-2021
DL6001-003
Crane 2000LE and 3000LE Wiring, Setup and Troubleshooting
In-ground Motion Assist 360 drive with Remote Control Enclosure
Chapter 9
9.9 Service panel (option) installation and wiring
Fig. 9.9.1 Service panel
1
Service
panel
DX4604-08C
3
RJ45 cover
4
RJ45
5
5/8"
undercut
flat
head machine screw,
6-32 thread, SS
Service
COM 2
Fig. 9.9.2 Control unit Service COM 2
1
RJ45
communication
cable,
20'
DX4662-003
Fig. 9.9.3
RJ45 handheld communication cable
9.9.1 Service panel installation.
1. Locate and install Service panel.
• Note cutout required for panel RJ45 port circuit
board.
• Fastener supplied is for installation to metal surface.
TIPS AND RECOMMENDATIONS
Service cable length: 20 feet.
9.9.2 Service
panel
wiring.
1. Route RJ45 cable (Fig. 9.9.3) from Service panel to
Motion Assist 360 control unit (Ref. Para. 9.2) in
Remote enclosure.
2. Plug RJ45 connector into Motion Assist 360 control
unit COM 2 connector.
NOTICE
Always use dormakaba handheld interface cable
DX4662!
Never use conventional network cable with
RJ 45 plug!
May cause permanent damage to handheld!
1
4
1
3
5
4