26
Crane 2000LE and 3000LE
05-2021
DL6001-003
Crane 2000LE and 3000LE Wiring, Setup and Troubleshooting
In-ground Motion Assist 360 drive with Remote Control Enclosure
Chapter 6
6.13.1 Route Motion Assist 360 drive extension cables
to remote enclosure.
1. Using a dedicated conduit for DC wiring, route power
extension cable (5) and Hall sensor extension cable (6)
from in-ground container to remote enclosure.
NOTICE
Reference Para. 6.9, Fig. 6.9.1 for overview of
conduit and cable routing to remote enclosure.
6.13.2 Connect operator Hall sensor extension cable.
1. Insert Hall sensor extension cable (6) plug into Drive
Unit Reference and Position Sensors receptacle (8) on
control unit.
NOTICE
Insure plug is fully inserted and locked in
receptacle.
6.13.3 Connect operator power extension cable.
1. Insert power extension cable (5) plug into Drive Unit
motor receptacle (9) on control unit.
NOTICE
Insure plug is fully inserted and locked in
receptacle.
6.13 Connect Motion Assist 360 drive extension cables to
Motion Assist 360 control unit in remote enclosure
5
Power
extension
cable
6
Hall sensor extension
cable
7
Motion
Assist
360
control unit
Fig. 6.13.1 Motion Assist 360 control unit and drive
extension cables
5
6
7
8
9
10
2
Fig. 16.13.3 Motion Assist 360 drive power extension cable DX6016-00X
1
Fig. 6.13.2
Motion Assist 360 Hall sensor extension cable DX6015-00X
2
Power
extension
cable
25'
DX6016-001
50'
DX6016-002
100'
DX6016-003
1
Hall sensor extension
cable
25'
DX6015-001
50'
DX6015-002
100'
DX6015-003
8
Control unit Hall
sensor receptacle
9
Control unit power
cable receptacle
10
Cable clamp