36
Crane 2000LE and 3000LE
05-2021
DL6001-003
Crane 2000LE and 3000LE Wiring, Setup and Troubleshooting
In-ground Motion Assist 360 drive with Remote Control Enclosure
Chapter 9
9.4 Emergency stop pushbutton installation and wiring
Fig. 9.4.1 Emergency stop pushbutton wiring
Fig. 9.4.2 Emergency Stop pushbuttons
Interior
Exterior
9.4.1 Emergency stop pushbutton installation.
1. Locate and install two Emergency stop pushbuttons,
one on interior side of door and one on exterior side of
door.
• Coordinate pushbutton installation locations with
customer's representative.
• Mechanical installation per manufacturer's
instructions.
WARNING
ANSI/BHMA 156.27, Para. 20:
Switch button shall be installed within 48"
[1220 mm] of the door and 24" [610 mm] to
48" [1220 mm] above the floor.
9.4.2 Emergency
Stop
pushbutton wiring.
1. Use 2 conductor, 18 AWG cable with color code:
• Black
• Red
2. Route cable from each Emergency stop pushbutton to
Motion Assist 360 control unit (Ref. Para. 22.2) in
remote enclosure.
3. Inside Emergency stop cable:
Terminate wires in Inside Emergency stop terminal
block as shown in Fig. 9.4.1.
4. Outside Emergency stop cable::
Terminate wires in Outside Emergency stop terminal
block as shown if Fig. 9.4.1.
5. Secure cables and wiring in canopy.
Emergency
stop exterior
5A
5
Red
Blk
Emergency
stop interior
Motion Assist 360
control unit
Inside
Outside
Red
Blk
2 conductor cable
18 AWG stranded wire
2 conductor cable
18 AWG stranded wire
5A
5
Red
Blk
Red
Blk
1
Emergency Stop
pushbutton
DX3413-010
2
E-Stop
mounting
housing DX3413-020
Fig. 9.4.3
Emergency Stop
pushbutton and holder
1
2