37
Crane 2000LE and 3000LE
05-2021
DL6001-003
Crane 2000LE and 3000LE Wiring, Setup and Troubleshooting
In-ground Motion Assist 360 drive with Remote Control Enclosure
Chapter 9
9.5 Mode switch installation and wiring
Fig. 9.5.1 Mode switch assembly example
1
2
3
4
5
1
Mode switch DX6008
2
Steel outlet box
3 Steel
outlet
box cover
4 Spacer
5
Phillips pan head screw,
SS
Fig. 9.5.2 Mode switch wiring
9.5.1 Install Mode switch.
1. Install Mode switch.
• Coordinate Mode switch location with customer's
representative.
1. Route cable from Mode switch to Motion Assist 360
remote enclosure control unit (Ref. Para. 9.3).
2. Terminate wires in Mode switch terminal block at
Motion Assist 360 control unit in Remote enclosure.
9.5.2 Mode switch wiring.
1. Use 6 conductor cable (18 AWG stranded wire)
with color code:
• Black
• White
• Red
• Green
• Brown
• Blue
2. Terminate wires in program switch as shown in
Fig. 9.5.2
22.5 mm
13 mm
3 mm
4
2
6
8
3
1
5
7
BLU
YEL
GRN
PNK
GRY
0V
Auto 1
Auto 2
Summer
6 conductor cable
18 AWG stranded wire
In Oper
ation
Summer
Auto 2
Auto 1
Lock
ed
Nigh
tbank
BL
U
GRN
YEL
GR
Y
PNK
Off