OP000440
6-4
Troubleshooting
SWING SYSTEM
ELECTRICAL SYSTEM
Problem
Cause
Remedy
No swinging motion
Swing brake valve faulty.
Replace brake valve.
Hydraulic timer faulty.
Replace timer.
Low brake release pressure.
Adjust pressures.
Swing motor failed.
Replace swing motor.
Remote control valve failed.
Replace control valve.
Wrong pilot line connection.
Reconnect pilot lines.
Swing motion jerky
Swing gear worn.
Replace swing gear.
Swing bearing damaged.
Replace bearing.
Improper lubrication.
Add grease.
Problem
Cause
Remedy
Battery will not hold a charge
Low battery power.
Replace batteries.
Alternator belt loose or bad.
Tighten or replace belt.
Loose or corroded terminals.
Tighten or replace as required.
Alternator faulty.
Repair or replace as required.
Low battery power
Internal battery short.
Replace battery.
Short circuit in wiring.
Repair as required.
Engine speed is not controllable
Speed control dial failure.
Replace control dial.
Throttle controller failure.
Replace controller.
Speed control motor failure.
Repair or replace as required.
Blown fuse.
Replace fuse.
Wiring harness damaged.
Repair or replace as required.
Connector failure.
Repair or replace as required.
Power mode selector does not
work
Blown fuse.
Replace fuse.
Instrument panel failed.
Replace instrument panel.
Connector failure.
Replace connector.
Wiring harness damaged.
Repair or replace as required.
e-EPOS controller failure.
Repair or replace as required
Summary of Contents for DX190W
Page 2: ......
Page 71: ...OP000528 2 3 Operating Controls ...
Page 128: ...OP000528 Operating Controls 2 60 CD Player Optional AST DIR FG000109 Figure 135 ...
Page 196: ......
Page 292: ...OP000530 Inspection Maintenance and Adjustment 4 96 ...