OP000530
4-17
Inspection, Maintenance and Adjustment
1.
Position the machine on firm, level ground. Lower boom
and position bucket on ground as shown in Figure 16.
2.
Set engine speed to "LOW IDLE."
3.
Set safety lever to and stand "LOCK" position.
4.
Check level gauge by opening right access door. Oil level
must be between marks on sight gauge.
5.
If the level is below "L" mark add oil.
A.
Shut down engine.
B.
The hydraulic tank is pressurized. Turn the breather
cap slowly to allow the pressurized air to vent.
C.
Remove upper cover hydraulic tank and add oil.
6.
If oil level is above the "H" mark drain oil.
A.
Shut down engine and wait for the hydraulic oil to
cool down.
B.
Drain the excess oil from drain valve (Figure 19) at
the bottom of tank into a suitable container, using a
hose connected to the valve.
NOTE:
Dispose of drained fluids according to local
regulations.
FG006594
Figure 16
H
L
FG003366
Figure 17
FG006595
Figure 18
IMPORTANT
Do not fill above "H" mark on sight gauge. Overfilling
can result in damage to equipment and oil leaking
from hydraulic tank due to expansion.
FG006596
2
1
Figure 19
Summary of Contents for DX190W
Page 2: ......
Page 71: ...OP000528 2 3 Operating Controls ...
Page 128: ...OP000528 Operating Controls 2 60 CD Player Optional AST DIR FG000109 Figure 135 ...
Page 196: ......
Page 292: ...OP000530 Inspection Maintenance and Adjustment 4 96 ...
Page 304: ...OP000440 6 8 Troubleshooting ...