OP000530
4-53
Inspection, Maintenance and Adjustment
2,000 HOUR / YEARLY SERVICE
Perform All Daily, 50, 250, 500 and 1,000
Hour Service Checks
Change Swing Reduction Device Oil
NOTE:
Change swing reduction device oil after first 250
hours of operation or rebuild and every 2,000 hours
thereafter.
1.
Set a container under excavator.
2.
Remove cap (3, Figure 95) and install hose (4) to drain the
swing reduction device oil.
NOTE:
Dispose of drained fluids according to local
regulations.
3.
After draining oil, remove hose and install cap.
4.
Remove breather/fill cap (2, Figure 94) and add oil to "H"
mark on dipstick (1).
FG006599
1
2
Figure 94
WARNING!
The gear oil is very hot after the machine has been
operating. Shut all systems down and allow them to cool.
FG006600
4
3
Figure 95
L
H
FG000419
Figure 96