3.2 Continued
SW-1 Switch
(Top 8 switches on
circuit board)
SW-2 Switch
(Bottom 8 switches on
circuit board)
ON
1
2
345678
SW 1
ON
1
2
345678
SW 2
Typical Settings
MUST use - OFF
MUST use - ON
Normal - OFF
Shadow Loop - ON
Normal - OFF
MUST use - OFF
MUST use - OFF
MUST use - OFF
Typical Settings
Opening - RT/LT
Normal -
ON
Normal -
ON
MUST use - OFF
MUST use - OFF
Normal - OFF
Normal - OFF
Normal - OFF
Switch 1 - Operator Opening Direction:
Must OPEN
the operator’s gate upon initial AC power up and
open command. If the first open command begins to close the gate, turn AC power off and reverse this
switch.
Switch 2 - Auto-Close Timer:
Turns the auto-close timer on or off. If auto-close is ON, maximum time
that can be set for is approximately 23 secs.
If auto-close is OFF, an open gate will not close until a manual input is received.
Switch 3 - EXIT Loop Port Output / Full Open Input:
Determines that a device wired to main terminal 4 is
a normal full open command (ON)
OR
terminal 4 becomes the output from the exit loop detector that
is plugged into the EXIT Loop port in the circuit board (OFF) (Used for specialized functions).
Switch 4 - Standard Reverse:
This switch
MUST
be turned OFF for the Model 6524. An input to main terminal 10 (Photo
Sensor)
AND/OR
Reverse Loops will reverse a
CLOSING gate back to open position
. If auto-timer is turned ON, timer will time
out and close the open gate.
Note:
SW 2, switch 4 MUST also be turned OFF when an external entrapment
device (Photo
Sensor) has been wired to main terminal 10 (see below).
DO NOT
turn this switch ON.
Switch 5 - Quick-Close Timer Override:
This switch
MUST
be turned OFF for the Model 6524.
DO NOT
turn ON.
Switches 6-7 - Relay:
These work in conjunction with each other and determine when the relay on the board (main terminals
13-14) will be activated. This relay can be used as a switch for various functions such as illuminating a warning light when the
gate is moving, or turning on a green light when the gate is full open.
Switch 8 - Accessory Power / Maglock Power:
A maximum of 500 mA of constant power is supplied to any accessory
connected to main terminals 11 and 12 when this switch is OFF.
Turn this switch ON ONLY if a magnetic lock is connected to main terminals 11 and 12. This applies magnetic lock power and
logic to these terminals which is a
Normally Closed
function: Power is shut off .5 sec. prior to gate starting and remains off
while gate is opening and in the open position. Power is turned on after gate is closed again.
Switches 1-2 - Select Operator Type:
Sets the type operator that will be used with the circuit board.
Switch 3 - Input Power Failure Mode:
When this switch is turned OFF and a AC input power failure
occurs, gate will continue to operate normally using ONLY battery back-up power. When battery
back-up power has been depleted, gate will remain
CLOSED
and operator will shut down. After AC input
power has been restored, gate will return to normal operation.
When this switch is turned ON, gate will automatically fully open and operator will shut down during an
AC input power failure. After AC input power has been restored, gate will close.
Switch 4 - Reverse/Shadow:
When this switch is turned
OFF,
external entrapment
device (Photo
Sensor) wired to main terminal 10 is a
standard reverse
input (see SW 1, switch 4 above).
This switch
MUST
be turned
ON
when using a
shadow loop
, see page 28 for more information about
shadow loop connection.
Switch 5 - Overlapping Dual Gates:
When the gate overlap is
OFF
, the gate operator(s) will start the
open and close cycles at the
same time
. This is the normal setting for a
single
gate operator. Turning the gate overlap
ON
when
using dual gate operators will cause the secondary operator to start the
open
cycle 1.5 seconds
before
the primary operator.
The primary operator will start the
close
cycle 1.5 seconds
before
the secondary operator.
Switch 6 - Circuit Board Power Management:
Turn
OFF
when using 115/230V input power to allow circuit board to have
constant
power.
DO NOT
turn ON.
Note:
ONLY turn this switch ON when using
solar power
. It minimizes the power drain by the circuit board. When the gate has
been closed for 5 min. or held open for 5 min., circuit board will power down. Main terminals 1, 2, 3 and loop detector ports will
remain powered up. An input from one of these connections will power up the circuit board again. NOT used for AC input power.
Switches 7-8 - Not Used:
These switches
MUST
be turned OFF for the Model 6524.
DO NOT
turn ON.
6524-065-R-12-17
22