12345678
ON
12345678
ON
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
EXIT
LOOP
REVERSE
LOOP
POWER SEL
AC POWER/SOLAR
REV SENSE
P3
SELF TEST
RESET
RED=CHARGING
GREEN=CHARGED
KEY
SWITCH
NO
NC
3 BUTTON
CONTROL
SW1
SW2
OFF
ON
POWER
P4
P2
1
6
TIME DELAY
9410
Single
Channel
9409
Dual
Channel
4100-010
1 2 3 4 5 6 7 8 9 10
1234
ON
OPEN BEAM
CLOSE BEAM
OPEN EDGE
CLOSE EDGE
SECTION 3 - ADJUSTMENTS
3.1 4100 Circuit Board Descriptions and Adjustments
Plug-In Loop Detectors
(Sold separately)
EXIT Loop T
erminal
REVERSE/SHADOW
Loop T
erminals
Shadow Output T
erminal
Self-test mode is for bench
checks ONLY! Operator
MUST
be disconnected from the gate.
The operator will continually
cycle the gate.
The jumper must be set
at normal mode for
normal operater function.
Self-Test
Mode
Normal
Mode
Limit/
Alarm
Plug P3
Terminal
10-Pin UL 325/
3 Button Station
Removable Terminal
See pages 26 and 27.
3 Button
Station
Jumper
See page 26.
20-Pin
Main Terminal
See pages 25 and 26.
Battery Plug P2 Terminal
Self-Test
Loop LEDs
Input LEDs
See page 25.
Tracker
Data
See page 28.
Input LEDs
should be OFF and will only illuminate when
the input that is next to the LED is activated. See page 25.
Limit LEDs
will only illuminate when the respective limit
switch has been activated.
Loop LEDs
will only illuminate when a reverse or exit
loop is activated (Vehicle passing over a loop).
Limit LEDs
3 Button LEDs
Battery Charging
LED Monitor
See pages 19
UL 325
DIP-switches
See page 27
Power Select Jumper
See Page 19
OPEN
CLOSE
STOP
Illuminated
LEDs
Indicates that low voltage
power is being applied to the circuit board.
How LEDs Function
Auto-close timer (when
turned on) SW 1, switch 2.
Time Delay:
Adjust from 1 second (full
counter-clockwise) to
approximately 23 seconds
(full clockwise).
Auto-Close Timer
ON
1
2
345678
SW 1
DIP-Switches
ON
1
2
345678
SW 1
ON
1
2
345678
SW 2
Set the DIP-switches
on the circuit board
to the desired
setting. See
switch-settings on
next 2 pages.
Adjust reversing sensitivity for the
open
AND
close direction of the
operator, See page 24.
Reverse Sensor
REV SENSE
Max
Min
LED
Reset Button:
Press after
changing a DIP-switch setting
on the board or if board locks
up during operation.
Board Relay
Dry relay contacts
(terminals 13-14) can
be set for Normally
Open (NO) or Normally
Closed (NC) operation
by placing the relay shorting bar on the N.O.
or N.C. pins respectively. SW 1, switches 6
and 7 must be set to control relay. See next
page for descriptions.
NC
NO
Key Switch:
Cycles the
operator when pressed. Will
use Auto-Close timer when turned ON.
Note:
If powering up operator using
ONLY DC power
, the key switch
MUST
be pressed
AFTER
DC power switch is
turned ON to power up operator.
Bi-Parting Gates Note:
MUST
be
pressed on
PRMARY
operator
FIRST
after powering up operators to establish
PRIMARY/Secondary operator order.
The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator(s) is
complete.
Whenever any of the programming DIP-switches on the circuit board are changed, ALL power must be shut-off,
and then turned back on OR press reset button on circuit board for the new setting to take effect.
All Power Switches
Note:
Alarm reset button
WILL NOT
reset circuit board after changing
DIP-switch settings. See page 29.
6524-065-R-12-17
20