HR100-CT
User Manual
Indicator
LED
(Red,
Green
&
Blue)
Base
Area
Mask
(Inner
3
Rows)
Area
Mask
(Outer
2
Rows)
Detection
Window
Potentiometer
(Sensitivity
Volume)
Connector
Depth Adjustment
Lever Arm
(Inner 3 Rows)
Cover
Depth Adjustment
Lever Arm
(Outer 2 Rows)
Dip
Switch
Dip
Switch
50mm
50mm
③
If you need to remove the sensor body from its base
then lift the sensor body from the base and tilt it
forward to remove as illustrated.
①
Attach the mounting template w i t h
i t s
b o t t o m
parallel
to
the
same
position
as
the bottom edge of
the door engine cover.
Sensor
’
s
Cable
Cable
Red
Black
White
Green
)
Gray(+)
R2,3,4,5
Output
AC/DC
12 to 24 [V]
±10%
R1,2
Output
Collector
Emitter
N.O.
COM
Power
(
Non
Pole
)
Test Input
Test-P
Test-N
Set
“
Test
input
”
dip
switch
setting
Y 6 to “ON”
Ref section 7, Dip Switch
Settings.
ON
6
English
Green
Standby.
Green blinking
Doorway
Learning (When dip switch Y 5 is ON).
Blue
ROW
4,5
Detecting.
Red
ROW
1,2,3
Detecting.
Orange
Detection
row
“
ROW1
”
(
“
ROW2
”
when doorway
Learning
is turned ON) is detecting door movement.
Orange
blinking
(Fast)
Indicates a change of dip switch settings.
Orange
blinking
(Slow)
Door
Hold is turned Open (When dip switch Y
4 is Open) .
Green/Red
blinking (Fast)
Internal
Sensor Error.
Green/Red
blinking (Slow)
Reflected infrared signal from the floor is very low.
Installation
Instruction
Accessories
Mounting
Template
Cable
Mounting
Screws
(2
pcs.)
1.
DESCRIPTION
3
Rows ON
2
Rows ON
4
Rows ON
5
Rows ON
Door
OFF
ON
☆
= Default Setting
When more than two sensors are installed in close proximity to each
other select different frequency settings for each sensor to prevent
cross interference.
Doorway
Learn
2.
DIMENSIONS
3.
LED
INDICATORS
5. TECHNICAL SPECIFICATIONS
6.
MOUNTING
&
WIRING
INFORMATION
7.
DIP
SWITCH
SETTINGS
Description
The sensor will detect a stationary object for the
period
of
the preset
presence timer setting on the inner 3 rows.
Possible Setting Options
Function
Presence
Timer
Quantity of
Detection
Rows
The number of rows of detection can be set to 5, 4, 3, 2 depending on
detection area requirements.
Frequency
Doorway Learn allows the 1
st
row of detection to be focused
inside the door close area without detecting the door movement.
O
N
Dip
Switch
Y
Dip
Switch
X
O
N
Dip Switch X
R5
☆
3
4
Disregarding
this
symbol
may
result
in
serious
injury
or
death.
Note
Special
attention
is
required
when
this
symbol
is
shown.
②
Dri l l h o l e s
f o r
mounting (3.5mm
φ
)
and wiring (10mm
φ
) holes.
Drilling
may
cause
electric
shock.
Be careful of hidden
wires
inside
the
door
engine cover.
④
Attach the sensor with the
mounting screws provided.
Note
⑤
-1
Wiring to a door controller that
can
test the sensor.
⑤
-2
Wiring to a door controller that
cannot
test the sensor.
OFF
1 2
3 4
5 6
7 8
1 2
3 4
5 6
Note
Y
X
Y
Set
“
Test
input
”
dip
switch
setting
Y 6 to “OFF”
Ref section 7, Dip Switch
Settings.
Note
To maximize the effectiveness of doorway detection, install the HR100-CT outside and inside as shown below.
Side View
WARNING
!
CAUTION
!
Disregarding
this
symbol
may
result
in
injury
or
damage
to
equipment.
3.0m
(9.84ft)
Max
50mm
A
B
Mounting height
is 3m (9.84ft) or
lower.
Mount within 50mm
from the bottom of the
door engine cover.
Ensure there are no
moving objects in the
detection zone.
Use different frequency
settings for sensors in
close proximity.
Ensure the minimum of
reflected sunlight from
the floor.
4. MOUNTING PRECAUTIONS
Ensure
no condensation
gets onto the sensor.
If possible ensure no
accumulation of snow or
water on the floor.
If the sensor is exposed
to excessive rain install
with a Hotron weather
cover.
WARNING
!
Sensor
’
s
Cable
Cable
Red
Black
White
Green
)
Blue(-)
Gray(+)
R2,3,4,5
Output
AC/DC
12 to 24 [V]
±10%
R1,2
Output
Collector
Emitter
N.O.
COM
Power
(
Non
Pole
)
ON
6
OFF
Y
do not connect
do not connect
⑦
Replace Cover.
Be careful not to inadvertently move the Depth Adjustment
Lever Arms when replacing the cover.
Depth
Adjustm
ent
Lever
Arm
⑥
House connectors in the receptacle.
CAUTION
!
A
B
Moving Door Leaf
Moving Door Leaf
A
B
Plan View
CAUTION
!
75mm(2.95")
=
Standard
Mounting
Pitch
25mm
(0.98")
15mm
(0.59")
35mm
(1.37")
10mm
(0.39")
230mm(9.06")
44mm
(1.73")
7
0
.4
m
m
(2
.7
7
")
6
6
.5
m
m
(2
.6
2
")
33.5
mm
(1.32")
Blue(-)
Brown(-)
Brown(-)
R4
3
4
R3
3
4
R2
3
4
2s
☆
1
2
30s
1
2
1
2
1
2
60s
∞
A
☆
5
6
B
5
6
5
6
5
6
C
D
5
5
Door
☆
When Doorway Learn is turned ON, the sensitivity level
of the inner row of detection is only at maximum when the
outer rows of detection are activated.
Activation
Relay
Output
N.O.
N.C.
☆
Monitor
Mode
Door Hold
Refer to [11.Timing Chart of events] for full details on Activation
Output.
When connected to a door controller without a TEST input, set to “OFF”.
When connected to a door controller with a TEST input, set to “ON”
Refer to [11.Timing Chart of events].
When set to ON, pedestrians moving away from the sensor will not be
detected.
Test Input
Setting
from Door
Controller
Reflection
Diagnostics
Set to Snow in instances where false door activations can result from
blowing snow, leaves or rubbish in the door close area.
Note
Transmitter
Receiver
IR
Spot
Receiver
IR
Spot
Transmitter
LED
☆
30s
1
2
R5
☆
3
4
A
☆
5
6
OFF
5
☆
To comply with EN16005 set the presence timer to 30s or
more.
Direction
Detection
Description
Possible Setting Options
Function
For pedestrian safety purposes when “Doorway Learn” is set
to ON the 1
st
and 2
nd
row of detection will detect pedestrians
regardless of direction of movement.
ON
1
1
OFF
☆
1
OFF
☆
2
Activation
Output
(Mechanical Relay)
2
To comply with EN16005
set to “ON”.
OFF
ON
☆
6
6
OFF
☆
A low reflected infrared signal is indicated by a slow flashing Red/Green
LED.
To ignore this low reflection error, set this dip switch to “Low
Reflection”(ON).
To comply with EN16005 set to “Normal”.
Low
Ref.
8
8
Normal
☆
8
Normal
☆
Snow
3
3
Normal
☆
3
Normal
☆
Switch to OPEN to hold the door in the open position.
7
Outer 2 rows
adjustment
lever arm
1.0
[m]
Inner 3
rows
adjustment
lever arm
0
2.2
Door
2.0
1.0
3.0
0.5
Area
Mask
(Inner
3
Rows)
Area
Mask
(Outer
2
Rows)
0
1.0
2.0
3.0[m]
8.DETECTION
AREA
WIDTH
AND
DEPTH
ADJUSTMENT
1.0
[m]
0
2.2
Door
2.0
1.0
3.0
0.5
1.5
1.5
[m]
1.0
0
2.2
Door
2.0
1.0
3.0
0.5
Door
0
2.2
2.0
1.0
3.0
1.0
0.5
[m]
[-8
degree]
setting
[0
degree]
setting
0
2.2
2.0
1.0
3.0
2.0
1.0
[m]
[0
degree]
setting
0
2.2
2.0
1.0
3.0
2.0
1.0
[m]
[0
degree]
setting
0
2.2
2.0
1.0
3.0
2.0
1.0
[m]
[+10
degree]
setting
0
2.2
2.0
1.0
3.0
2.0
1.0
[m]
3.0
[+10
degree]
setting
With
Base
Without
Base
Detection Area Depth Adjustment: Inner 3 Rows
Detection Area Depth Adjustment: Outer 2 Rows
Detection Area Width Adjustment
2.0
1.0
1.0
2.0
Narrow
Wide
With
Base
Without
Base
[-8
degree]
setting
[0
degree]
setting
The above illustrated detection areas represent the actual position of the infrared beams. The actual detection area observed will vary depending on the
sensor installation environment, object
been
detected
and
sensor
settings.
Please ensure that the detection area is set to conform to EN16005.
CAUTION
!
CAUTION
!
Open
4
4
Auto
☆
4
Auto
☆
1
1
2
0.55
[lb.]
(0.25
[kg])
Cable,
Mounting
Screw
2pcs.,
Mounting
Template,
Installation
Instruction
-20
to
+60
[Deg.C],(-4
to
140
Deg.F)
Below 80%
Open
collector:
7.5
[mA]
(Max) Resistor Load
Opto coupler (NPN)
Voltage: 55 [VDC] Max. Current : 50 [mA] Max.
Dark Current: 100 [nA] Max. (Resistance load)
Form
A
Relay DC50
[V]
0.1[A] Resistor Load
6 [mA] Max.
@ 24 [VDC]
Model
Name
HR100-CT
Active
Infrared
Reflection
Installation
Height
3.0[m]
(9.84
[ft])
Max
Detection
Method
Approx. 0.5s
Output
Holding
Time
Presence
Timer
1
[seconds]
Outer
2
Rows
Inner
3
Rows
0.1s
~
0.2s
Output
Weight
Accessories
Black,
Silver
Test
Input
Operating
Temperature
Operating humidity
Response
Time
Supply Voltage
2s,30s,60s or
∞
AC/DC 12 to 24 [V] ±10% 50/60Hz
Power
Consumption
AC12V-2.1
[VA]
(Max)
AC24V-2.1 [VA] (Max)
DC12V-110
[mA]
(Max)
DC24V-60
[mA]
(Max)
Color
ROW
1,2
ROW
2,3,4,5
Category
2
,
performance
level
D according to EN ISO 13849-1:2008
IP
Rate
IP54
(With Base)
Notice:
Specification
may
be
changed
without
prior
notice.
Dip Switch Y
0v
ON
Without TEST
With TEST
Without TEST
0v
OFF
Width
Narrow
Wide
Safety
Relay
Output
N.O.
N.C.
☆
Refer to [11.Timing Chart of events] for full details on Safety
Output.
Safety
Output
(Opto-Coupler)
7
7
N.O.
☆
N.O.
N.C.
☆
N.O.
☆
COMPLIED
STANDARDS
DIN18650-1:2005
EN 12978:2003
EN 16005:2012
EC type examination 44 205
12 414283-001
Setting
required
to
conform
with
EN16005.
EN16005
EN16005
EN16005
EN16005
EN16005