background image

HR100-CT

User Manual

Indicator

 

LED

(Red,

 

Green

 

&

 

Blue)

Base

Area

 

Mask

(Inner

 

3

 

Rows)

Area

 

Mask

(Outer

 

2

 

Rows)

Detection

 

Window

Potentiometer
(Sensitivity

 

Volume)

Connector

Depth Adjustment
Lever Arm
(Inner 3 Rows)

Cover

Depth Adjustment
Lever Arm
(Outer 2 Rows)

Dip

 

Switch

Dip

 

Switch

50mm

50mm

 If you need to remove the sensor body from its base 

then  lift  the  sensor  body  from  the  base  and  tilt  it 
forward to remove as illustrated.

  Attach  the  mounting  template  w i t h

 

i t s

 

b o t t o m 

parallel

 

to

 

the

 

same

 

position

 

as

 

the bottom edge of 

the door engine cover.

Sensor

s

 

Cable

Cable

Red

Black

White

Green

)

Gray(+)

R2,3,4,5

  

Output 

AC/DC 
12 to 24 [V] 
±10%

R1,2

 

Output 

Collector

Emitter

N.O.

COM

 

Power

Non

 

Pole

Test Input

Test-P

Test-N

Set

 

Test

 

input

 

dip

 

switch

 

setting

  

Y  6 to “ON”

Ref section 7, Dip Switch 
Settings.

ON

6

English

Green

Standby.

Green blinking 

Doorway

 

Learning (When dip switch  Y  5 is ON).

Blue

ROW

 

4,5

 

Detecting.

Red

ROW

 

1,2,3

 

Detecting.

Orange

Detection

 

row

 

ROW1

(

ROW2

 

when doorway 

Learning

 

is turned ON) is detecting door movement.

Orange

 

blinking

 

(Fast)

Indicates a change of dip switch settings.

Orange

 

blinking

 

(Slow)

Door

 

Hold is turned Open (When dip switch  Y

 

 4 is Open) .

Green/Red

 

blinking (Fast) 

Internal

 

Sensor Error.

Green/Red

 

blinking (Slow) 

Reflected infrared signal from the floor is very low.

Installation

 

Instruction

Accessories

Mounting

 

Template

Cable

Mounting

  

Screws

 

(2

 

pcs.)

1.

 

DESCRIPTION

3

 

Rows ON

2

 

Rows ON

4

 

Rows ON

 

5

 

Rows ON

 

Door

OFF

ON

 = Default Setting

When more than two sensors are installed in close proximity to each 

other  select  different  frequency  settings  for  each  sensor  to  prevent 

cross interference. 

Doorway 
Learn 

2.

 

DIMENSIONS

3.

 

LED

 

INDICATORS

5. TECHNICAL SPECIFICATIONS

6.

 

MOUNTING

 

&

 

WIRING

 

INFORMATION

7.

 

DIP

 

SWITCH

 

SETTINGS

Description

The sensor will detect a stationary object for the

 

period

 

of

 

the preset 

presence timer setting on the inner 3 rows. 

Possible Setting Options

Function

Presence 
Timer

Quantity of 
Detection 
Rows

The number of rows of detection can be set to 5, 4, 3, 2 depending on 

detection area requirements.

Frequency

Doorway  Learn  allows  the  1

st

  row  of  detection  to  be  focused 

inside the door close area without detecting the door movement. 

O

N

Dip

 

Switch

  

Y

Dip

 

Switch

  

X

O

N

Dip Switch  X

R5

3

4

Disregarding

 

this

 

symbol

 

may

 

result

 

in

 

serious

 

injury

 

or

 

death.

Note

Special

 

attention

 

is

 

required

 

when

 

this

 

symbol

 

is

 

shown.

  Dri l l  h o l e s

 

f o r

 

mounting  (3.5mm

φ

and wiring (10mm

φ

) holes.

Drilling

 

may

 

cause

 

electric

 

shock.

Be careful of hidden

 

wires

 

inside

 

the

 

door

 

engine cover.

  Attach  the  sensor  with  the 

mounting screws provided.

Note

-1

 

 Wiring to a door controller that 

can

 test the sensor.

-2

  

Wiring to a door controller that 

cannot 

test the sensor.

OFF

1 2

3 4

5 6

7 8

1 2

3 4

5 6

Note

Y

X

Y

Set

 

Test

 

input

 

dip

 

switch

 

setting

  

Y  6 to “OFF”

Ref section 7, Dip Switch 
Settings.

Note

To maximize the effectiveness of doorway detection, install the HR100-CT outside and inside as shown below.

Side View

WARNING

!

CAUTION

!

Disregarding

 

this

 

symbol

 

may

 

result

 

in

 

injury

 

or

 

damage

 

to

 

equipment.

3.0m

 

(9.84ft)

Max

 

50mm

A

B

Mounting  height 
is 3m (9.84ft) or 
lower.

Mount  within  50mm 
from the bottom of the 
door engine cover.

Ensure  there  are  no 
moving  objects  in  the 
detection zone.

Use  different  frequency 
settings  for  sensors  in 
close proximity.

Ensure  the  minimum  of 
reflected  sunlight  from 
the floor.

4. MOUNTING PRECAUTIONS

Ensure

 

no condensation 

gets onto the sensor.

If  possible  ensure  no 
accumulation of snow or 
water on the floor.

If the sensor is exposed 
to excessive rain install 
with  a  Hotron  weather 
cover.

WARNING

!

Sensor

s

 

Cable

Cable

Red

Black

White

Green

)

Blue(-)

Gray(+)

R2,3,4,5

  

Output 

AC/DC 
12 to 24 [V] 
±10%

R1,2

 

Output 

Collector

Emitter

N.O.

COM

 

Power

Non

 

Pole

ON

6

OFF

Y

do not connect

do not connect

 Replace Cover.

Be careful not to inadvertently move the Depth Adjustment 
Lever Arms when replacing the cover.

Depth

Adjustm

ent

Lever

Arm

 House connectors in the receptacle.

CAUTION

!

A

B

Moving Door Leaf

Moving Door Leaf

A

B

Plan View

CAUTION

!

75mm(2.95")

 

=

 

Standard

 

Mounting

 

Pitch

25mm

(0.98")

15mm

(0.59")

35mm

(1.37")

10mm

(0.39")

230mm(9.06")

44mm

(1.73")

7

0

.4

 

m

m

(2

.7

7

")

6

6

.5

 

m

m

(2

.6

2

")

33.5

 

mm

(1.32")

Blue(-)

Brown(-)

Brown(-)

R4

3

4

R3

3

4

R2

3

4

2s

1

2

30s

1

2

1

2

1

2

60s

A

5

6

B

5

6

5

6

5

6

C

D

5

5

Door

When  Doorway  Learn  is  turned  ON,  the  sensitivity  level 

of the inner row of detection is only at maximum when the 
outer rows of detection are activated.

Activation
Relay
Output

N.O.

N.C.

Monitor 
Mode

Door Hold

Refer to [11.Timing Chart of events] for full details on Activation

 

Output. 

 

 

When connected to a door controller without a TEST input, set to “OFF”. 
When connected to a door controller with a TEST input, set to “ON”
Refer to [11.Timing Chart of events].

When  set  to  ON,  pedestrians  moving  away  from  the  sensor  will  not  be 
detected.

Test Input 
Setting 
from Door 
Controller

Reflection 
Diagnostics

 

Set to Snow in instances where false door activations can result from 
blowing snow, leaves or rubbish in the door close area.

Note

Transmitter

Receiver

IR

 

Spot

 

 

Receiver

IR

 

Spot

 

Transmitter

LED

30s

1

2

R5

3

4

A

5

6

OFF

5

To comply with EN16005 set the presence timer to 30s or 

more.

Direction 
Detection

Description

Possible Setting Options

Function

For pedestrian safety purposes when “Doorway Learn” is set 
to ON the 1

st

 and 2

nd

 row of detection will detect pedestrians 

regardless of direction of movement.

ON

1

1

OFF

1

OFF

2

Activation

 

Output

   

(Mechanical Relay)

2

To comply with EN16005

 

set to “ON”. 

OFF

ON

6

6

OFF

A low reflected infrared signal is indicated by a slow flashing Red/Green 
LED.
To  ignore  this  low  reflection  error,  set  this  dip  switch  to  “Low 

Reflection”(ON). 

To comply with EN16005 set to “Normal”.

Low

 

Ref.

8

8

Normal

8

Normal

Snow

3

3

Normal

3

Normal

Switch to OPEN to hold the door in the open position. 

7

Outer 2 rows 
adjustment 
lever arm

1.0

[m]

Inner 3 
rows 
adjustment 
lever arm

0

2.2

Door

2.0

1.0

3.0

0.5

Area

 

Mask

 

(Inner

 

3

 

Rows)

Area

 

Mask

 

(Outer

 

2

 

Rows)

0

1.0

2.0

3.0[m]

8.DETECTION

 

AREA

 

WIDTH

 

AND

 

DEPTH

 

ADJUSTMENT

1.0

[m]

0

2.2

Door

2.0

1.0

3.0

0.5

1.5

1.5

[m]

1.0

0

2.2

Door

2.0

1.0

3.0

0.5

Door

0

2.2

2.0

1.0

3.0

1.0

0.5

[m]

[-8

 

degree]

 

setting

[0

 

degree]

 

setting

0

2.2

2.0

1.0

3.0

2.0

1.0

[m]

[0

 

degree]

 

setting

0

2.2

2.0

1.0

3.0

2.0

1.0

[m]

[0

 

degree]

 

setting

0

2.2

2.0

1.0

3.0

2.0

1.0

[m]

[+10

 

degree]

 

setting

0

2.2

2.0

1.0

3.0

2.0

1.0

[m]

3.0

[+10

 

degree]

 

setting

With 

Base

 

Without 

Base

Detection Area Depth Adjustment: Inner 3 Rows

Detection Area Depth Adjustment: Outer 2 Rows

Detection Area Width Adjustment

2.0

1.0

1.0

2.0

Narrow

Wide

With 

Base

 

Without 

Base

[-8

 

degree]

 

setting

[0

 

degree]

 

setting

The above illustrated detection areas represent the actual position of the infrared beams. The actual detection area observed will vary depending on the 
sensor installation environment, object

 

been

 

detected

 

and

 

sensor

 

settings.

 

Please ensure that the detection area is set to conform to EN16005. 

CAUTION

!

CAUTION

!

Open

4

4

Auto

4

Auto

1

1

2

0.55

 

[lb.]

 

(0.25

 

[kg])

Cable,

 

Mounting

 

Screw

 

2pcs.,

 

Mounting

 

Template,

 

Installation

 

Instruction

-20

 

to

 

+60

 

[Deg.C],(-4

 

to

 

140

 

Deg.F)

Below 80% 

Open

 

collector:

 

7.5

 

[mA]

 

(Max) Resistor Load 

Opto coupler (NPN) 
Voltage: 55 [VDC] Max. Current : 50 [mA] Max.
Dark Current: 100 [nA] Max. (Resistance load)

Form

 

A

 

Relay DC50

 

[V]

 

0.1[A] Resistor Load 

6 [mA] Max.

 

@ 24 [VDC]

Model

 

Name

HR100-CT

 

Active

 

Infrared

 

Reflection

Installation

 

Height

3.0[m]

  

(9.84

 

[ft])

  

Max

Detection

 

Method

Approx. 0.5s

Output

 

Holding

 

Time

Presence

 

Timer

1

 

[seconds]

Outer

 

2

 

Rows

Inner

 

3

 

Rows

0.1s  

  0.2s

Output

Weight

Accessories

Black,

 

Silver

Test

 

Input

Operating

 

Temperature

Operating humidity

Response

 

Time

Supply Voltage

2s,30s,60s or 

  

AC/DC 12 to 24 [V] ±10% 50/60Hz

  

 

Power

 

Consumption

AC12V-2.1

 

[VA]

 

(Max)

       

AC24V-2.1 [VA] (Max)

DC12V-110

 

[mA]

 

(Max)

      

DC24V-60

 

[mA]

 

(Max)

Color

ROW

 

1,2

ROW

 

2,3,4,5

Category

2

 

,

 

performance

 

level

 

D according to EN ISO 13849-1:2008

IP

 

Rate

IP54

 

(With Base)

Notice:

  

Specification

 

may

 

be

 

changed

 

without

 

prior

 

notice.

Dip Switch  Y

0v

ON

Without TEST

With TEST    

Without TEST

0v

OFF

Width

Narrow

Wide

Safety
Relay
Output

N.O.

N.C.

Refer to [11.Timing Chart of events] for full details on Safety

 

Output. 

 

 

Safety

 

Output 

  

(Opto-Coupler)

7

7

N.O.

N.O.

N.C.

N.O.

COMPLIED

 

STANDARDS

DIN18650-1:2005

EN 12978:2003
EN 16005:2012

EC type examination 44 205 

12 414283-001

Setting

 

required

 

to

 

conform

 

with

 

EN16005.

EN16005

EN16005

EN16005

EN16005

EN16005