4.3 Entrapment Protection Wiring
Open Beam
Close Beam
Reversing Edge
(Wireless Optional)
To Com
To Edge/Beam
Input
UL 325 DIP-Switches
Main
Terminal
Monitored Device Note:
Only 1 monitored
Device can be connected to each input. An
OPTIONAL
Expansion Board (sold separately)
will allow connection for additional devices.
Edge/Beam Inputs (3 & 4) Note:
Open
/
Close
Edge/Beam inputs will activate in
EITHER
direction of gate travel.
When using dual operators
: a edge/beam can be connected from the primary
gate to #3 and the secondary gate’s edge/beam can be connected to #4.
All potential entrapment areas MUST be protected with an
external entrapment protection device. See pages 16 & 17.
At least ONE external entrapment protection device MUST
be installed or the operator will NOT function.
12345678
ON
12345678
ON
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
EXIT
LOOP
REVERSE
LOOP
AC POWER/SOLAR
POWER SEL
REV SENSE
JUMPER ON
SOLAR MODE
P3
SELF TEST
RESET
RED=CHARGING
GREEN=CHARGED
KEY
SWITCH
NO
NC
3 BUTTON
CONTROL
SW1
SW2
OFF
ON
POWER
P4
P2
1
6
TIME DELAY
1 2 3 4 5 6 7 8 9 10
UL 325 Terminal
External Entrapment Protection
Device Connection
Common
Common
CLOSE Edge/Beam Reverse
OPEN Edge/Beam Reverse
CLOSE Beam Reverse
OPEN Beam Stop
Common
Common
CLOSE Edge/Beam Reverse (Switch 4)
OPEN Edge/Beam Reverse (Switch 3)
CLOSE Beam Reverse (Switch 2)
OPEN Beam Stop (Switch 1)
1 2 3 4 5 6
7 8 9 10
1 2 3 4 5 6
7 8 9 10
Com
to UL 325
Terminal
to UL 325
Terminal
24VDC 500 mA
MAX
ON
1
2
34567
8
SW 1
Photo Sensors POWER:
Terminal 12 supplies 24 VDC, 500 mA of
constant power for desired
accessories
.
SW1,
switch 8
MUST be OFF
1234
ON
OPEN BEAM
CLOSE BEAM
OPEN EDGE
CLOSE EDGE
ONLY connect monitored devices.
Edge/Beam Inputs Note:
(3) Open
and
(4) Close
inputs
will activate in
EITHER
direction of gate travel.
1234
ON
OPEN BEAM
CLOSE BEAM
OPEN EDGE
CLOSE EDGE
Switch 1
Switch 2
Switch 3
Switch 4
DIP-switches
MUST
be turned
ON
for each device wired to terminal.
1234
ON
OPEN BEAM
CLOSE BEAM
OPEN EDGE
CLOSE EDGE
DIP-switches
MUST
be turned
ON
for each device
wired to terminal.
All safety devices are
wired to the
PRIMARY
operator when using
dual gate operators.
Primary operator is determined by pressing its
KEY
SWITCH
FIRST
after powering up operators.
This establishes Primary/Secondary operator order.
OPTIONAL Wireless Note:
Refer to the instruction
sheet that comes with the
receiver/transmitter for
more specific wiring and
mounting instructions.
To #3 Power
To Common
12345678
ON
12345678
ON
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
EXIT
LOOP
REVERSE
LOOP
IN POWER/BATT
PWR
SEL
REV SENSE
JUMPER ON
SOLAR MODE
P3
SELF TEST
RESET
RED=CHARGING
GREEN=CHARGED
KEY
SWITCH
NO
NC
3 BUTTON
CONTROL
SW1
SW2
OFF
ON
POWER
P4
P2
1
6
TIME DELAY
4100-010
1 2 3 4 5 6 7 8 9 10
24 VAC
Wireless
Receiver
for
Reversing
Edge
1234
ON
OPEN BEAM
CLOSE BEAM
OPEN EDGE
CLOSE EDGE
Main Terminal #3 Note:
Exceeding 250 mA of power from
this terminal may cause the circuit
board transformer to overheat,
causing intermittent problems.
6524-065-R-12-17
27