KEY
SWITCH
NO
NC
3 BUTTON
CONTROL
SW1
SW2
OFF
ON
POWER
P4
6
1 2 3 4 5 6 7 8 9 10
Low Voltage Common
Full Open
Full Open / Loop out
Low Voltage Common
Full Open
Low Voltage Common
Do Not Use
Low Voltage Common
Reverse / Shadow
Low Voltage Common
24 VDC Accessories / Maglock
Relay
Relay
Low Voltage Common
Bi-Parting
Bi-Parting
Common
Tracker Data
Tracker In
3 Button Station
•
Use a standard
4-wire
3-button
control station.
DoorKing’s
3-wire
3-button
control station
cannot
be used.
•
When using a 3-button control
station, the 3-pin jumper MUST
be set to
ON
.
•
See page 26 for wiring.
UL 325
See page 27
3-Button
Station
Relay
Contacts
3 Button
LEDs
10
13
14
18
17
16
OPEN Beam
CLOSE Beam
OPEN Edge
CLOSE Edge
Low V
oltage Common
Low V
oltage Common
OPEN
CLOSE
STOP
Common
4
OFF
ON
OPEN
STOP
CL
OS
E
W
Main Terminal Input
LEDs Note:
The LED
that is beside the main
terminal wiring input
will light when that
terminal input gets
activated.
W
M
M
M
L
tha
WE
M
M
M
L
th
WE
M
M
M
M
L
L
L
L
th
h
E
M
M
M
M
L
L
L
L
th
h
h
h
E
M
M
M
M
L
L
L
th
h
h
E
M
M
M
L
L
L
th
E
E
M
M
L
t
ER
R
M
M
t
ER
R
M
R
R
R
R
Operation of relay is dependent on
setting of SW 1,
switches 6 and 7
.
Relay contacts
can be set for
Normally Open (NO) or Normally
Closed (NC) operation.
Contact rating is
1 amp maximum
at 24-volts DC.
ON
12
3
4
5
67
8
SW 1
NC
NO
ON
1
2
34567
8
SW 1
SW1,
switch 8 OFF
: 24-VDC,
500 mA constant power can be
provided for desired accessories
wired to terminal 12 when the
maglock is
NOT
used.
Photo
Sensor
Maglock
SW1,
switch 8
ON
: 24-VDC
Maglock
power is provided
except
when the gate is
opening
or
open
(Normally Closed function). 1 Amp Max.
Main T
erminal Input LEDs
#2
#4
#6
#8
#10
QUICK GUIDE: Terminal Descriptions
See page 26 for terminal wiring.
UL 325/3 Button
10-Pin Terminal
•
lf SW 1,
switch 3
is
ON
, functions as a
normal full open input (Normal setting).
•
lf SW 1,
switch 3
is
OFF
, input to
terminal #4 becomes the output from the
EXIT loop detector plugged into the EXIT
loop port. (Used for specialized functions).
ON
12
3
45678
SW 1
12
•
SW 1,
switch 4
MUST be
OFF.
SW 2,
switch 4
MUST be
OFF.
When gate is
closing, an input to main terminal 10 (eg:
photo beam gets blocked) will
reverse
and
open the gate.
Note:
If the auto-close timer
is
ON
, when gate reaches the open position,
timer will time out and close the gate.
•
DO NOT
turn SW 1, switch 4
ON
.
•
DO NOT
turn SW 2, switch 4
ON
.
Note:
Main terminal 10 is not available for a
photo sensor when using a SHADOW LOOP.
See page 28 about shadow loop connection.
ON
12
3
4
5678
SW 1
ON
12
3
4
5678
SW 2
This input ONLY functions when gate is
fully opened
or in the
closing cycle
.
19 20
Connects to a
DoorKing Tracker Expansion
Board
. Data will be reported about this
gate
operator’s SPECIFIC activity
to a DoorKing
access control system. A list of the events
will be “Tracked” and stored in the access
control system.
Bi-Parting Gates ONLY.
Connect the
secondary gate operator terminals
16-17-18 to this primary
terminal 16-17-18 respectively.
16 and 17 wires
MUST
be twisted together.
Primary operator is determined by pressing its
KEY SWITCH
FIRST
after powering up operators.
This establishes Primary/Secondary operator order.
IMPOR
TANT
: Sec
on
dar
y
opera
tor
opens
FIRST
when using
overlapping bi-partin
g gates.
See p
age 13.
Main Terminal #3 Note:
Exceeding 250 mA of power from this terminal
may cause the circuit board transformer to
overheat, causing intermittent problems.
24 VDC - 250 mA max.
(See note above)
6524-065-R-12-17
3
Quick Guide - 2