ON
OFF
Opens
Clockwise
Opens
Counter-Clockwise
3.2 DIP-Switch Settings for 4100 Circuit Board
Switch
Function
Setting
Description
SW 1 (Top 8 Switches)
Operator
Opening
Direction
OFF
ON
OFF
ON
OFF
ON
OFF
ON
6-
OFF
6-OFF
6-ON
6-ON
7-
OFF
7-ON
7-OFF
7-ON
Auto-Close
Timer
Accessory Power/
Maglock Power
Relay:
Main Terminals
Terminal 13-14
1
2
3
4
5
8
6 and 7
The output wired to main terminal 4 becomes the output from the exit loop detector
plugged into the EXIT Loop port.
Normal Setting.
Main terminal 4 is a normal full open input.
Auto-close timer is OFF. Manual input required to close gate.
Normal Setting.
Auto-close timer is ON. Adjustable from 1-23 seconds.
500 mA
Constant power
for accessories connected to main terminal 12.
Normally Closed power
for Maglock connected to main terminal 12.
OFF
ON
Quick-close feature is OFF.
Quick-close feature is ON. Opening gate will stop and begin to close as soon as
all reversing inputs (Reverse loops, photo sensors) are cleared regardless of the
distance the gate has opened. Used for slide gates only.
OFF
ON
Main terminal 10 is a REVERSE input.
Turn
ON
when using a
SHADOW
loop.
Normal Setting.
Relay activates when gate is at open limit.
Relay activates when gate is not closed.
Relay activates when gate is opening and open.
Relay activates during opening and closing cycle.
1-OFF
1-OFF
1-ON
1-ON
2-OFF
2-ON
2-OFF
2-ON
Select
Operator
Type
1 and 2
DO NOT USE
for the 6524.
Slide Gate Operator
Swing Gate Operator
DO NOT USE
for the 6524.
Barrier Gate Operator
DO NOT USE
for the 6524.
Overhead Gate Operator
Switch
Function
Setting
Description
SW 2 (Bottom 8 Switches)
Switches 7 and 8
MUST
be turned
OFF
for Model 6524 operator.
OFF
Reverse/Shadow
Input
Overlapping
Bi-Parting Gates
3
4
7 and 8
6
OFF
ON
5
Single gate operator setting or overlapping gates start to open at same time.
Overlapping gates
ARE
used (Bi-Parting gates ONLY). Secondary gate starts to
open a few seconds before primary gate starts.
Changes direction
operator will cycle open
upon initial power up
and open command.
Reverses Gate
Not Used
Quick-Close
Timer Override
(Slide Gates
ONLY)
Exit Loop Port
Output
Full Open Input
Input to main terminal 10 and/or reverse loops will
reverse
gate during
close
cycle.
Do Not
use this setting for the 6524.
The two DIP-switches located on the circuit board are used to program the operator to operate in various modes and to turn on
or off various operating features. Whenever a switch setting is changed, reset button on circuit board must be pressed for the
new setting to take affect.
OFF
ON
Input Power
Failure Mode
Normal Setting.
Gate
operates normally
using ONLY battery back-up power.
After batteries are depleted, gate will remain
CLOSED
until AC power is restored.
Gate
fully opens
and operator
shuts down
until AC input power is restored.
OFF
ON
Circuit Board
Power
Management
Used for
115/230 VAC
input power. Board receives
Constant power
.
Used for
Solar
input power. Board
Minimizes power
when not in use. All terminals
shut down power except
main terminals 1, 2, 3
and
loop detector ports
.
Not Used
Setting
MUST
be used
6524-065-R-12-17
21