Automatic exit loop lead in wires
are twisted approx. 6 twists per
foot.
Reverse loop lead in wires
are twisted approx. 6 twists
per foot and are wired in
series.
Shadow loop lead in wires are
twisted approx. 6 twists per foot.
Reverse
Reverse
Automatic Exit
Shadow
4.4 Loop Detector Wiring
•
Loop detector wiring is shown for DoorKing
plug-in loop detectors. If other loop detectors are
used, refer to the installation instructions supplied
with those detectors for wiring instructions.
•
If other detectors are used, use a separate power
supply to power these detectors.
•
Loop layout shown is for a typical swing gate
application with two-way traffic, or one-way exit
only
traffic.
Com
N.O.
Shadow
Loop Output
DoorKing offers a free “
Loop and
Loop-Detectors Information
Manual
” PDF located at
DoorKing’s web site for more
information. www.doorking.com
DoorKing Plug-In
Loop Detectors
LOOP 1
LOOP 2
LOOP 1
To help protect the operator from accidentally closing on vehicles
in the gate’s path, DoorKing highly recommends that loops and
loop detectors be installed. Loops are laid underneath, cut into
asphalt or concrete driveways or buried beneath gravel and earth
driveways. A loop detection system will sense a vehicle like a
metal detector and send a signal to the gate operator preventing
the gate from automatically opening or closing on a vehicle
when it is in the gate’s path. DoorKing recommends that a
licensed installer perform this work.
Reverse Loops
are placed on
each side of the gate to prevent the gate
from closing on a vehicle in the gate’s
path. They will stop or reverse the
cycling of the gate while a vehicle is in
or near the gate’s pathway.
Shadow Loop
will
ONLY HOLD
the
main gates in the
Full Open Position
when
a vehicle is on the shadow loop. However,
it
WILL NOT stop or reverse
the main
gates once they start to close.
Automatic Exit Loop
Automatically opens the gate for exiting
vehicles without having to use a transmitter or
keypad. The exit loop can be placed a minimum of 4
feet away from the reverse loop or far enough away from
the gate so the gate has started opening or even completely
opened by the time you drive up to it (Free exit).
4 Ft. min. to avoid gate
movement inter
ference.
4 Ft. min. to avoid reverse
loop inter
ference.
12345678
ON
12345678
ON
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
EXIT
LOOP
REVERSE
LOOP
REV SENSE
JUMPER ON
SOLAR MODE
P3
SELF TEST
RESET
RED=CHARGING
KEY
SWITCH
NO
NC
3 BUTTON
CONTROL
SW1
SW2
OFF
ON
POWER
P4
P2
1
6
TIME DELAY
9410
Single
Channel
9409
Dual
Channel
4100-010
1 2 3 4 5 6 7 8 9 10
RED CHARGING
HA
G
Exit Loop Port
E
Reverse Loop Port
Swing Gate,
Shadow Loop
Dip Switch
Note:
SW 2,
switch 1
OFF
,
switch 2
ON
,
switch 4
ON
.
ON
12
3
4
5678
SW 2
Shadow
#10
1234
ON
OPEN BEAM
CLOSE BEAM
OPEN EDGE
CLOSE EDGE
All loop detectors are
wired to the
PRIMARY
operator when using
dual gate operators.
Primary operator is determined
by pressing its
KEY SWITCH
FIRST
after powering up
operators. This establishes
Primary/Secondary operator order.
6524-065-R-12-17
2
8