GENERAL 
INSTALLATION,
OPERATION,
MAINTENANCE,
and PARTS MANUAL
for your

1510 SWING-GATE 
OPERATOR MODEL "F"

HEAVY DUTY & EXTRA HEAVY DUTY

C

R

O

W

N

N D U S T R

A

I

I

L

O P E R A T O R S

Summary of Contents for AUT-O-DOR 1510

Page 1: ...rancisco CA 94080 Phone 650 952 5150 Fax 650 873 1495 website www crown industrial com Copyright Crown Industrial Operators 2011 GENERAL INSTALLATION OPERATION MAINTENANCE and PARTS MANUAL for your 1510 SWING GATE OPERATOR MODEL F HEAVY DUTY EXTRA HEAVY DUTY C R O W N N D U S T R A I I L O P E R A T O R S ...

Page 2: ...er Replacement Parts 9 B Parts List 9 Parts List Heavy Duty 1 2 3 4 1 HP Operator 10 Parts List Extra Heavy Duty 1 HP Operator 12 WARRANTY 14 Note We reserve the right to modify or change without prior notice any statements or information contained herein If exact dimensions or specifications are required by the customer certified prints will be furnished without charge upon request to Crown Indus...

Page 3: ...AFTS AND GEARS Shafts and gears in the heavy unit are mounted in long life bearings enclosed in an oil tight housing and operate at all times in a bath of grease extra heavy duty units are oil filled The automatic limit switch is built on the reduction unit and stops the gate in the desired open or closed position 4 CRANK AND CONNECTING ARMS The operating levers consist of a heavy duty crank and c...

Page 4: ...in concrete piers considering the angle of the gate in the full open position The size and depth of the piers may vary with soil and fill types NOTE The customer and or contractor is responsible for the proper installation of the mounting posts The posts must be installed plumb and in exact position as shown on Figure 3 or 4 b The top of the channel post should be positioned vertically one inch be...

Page 5: ...ND A B C D 90 2 6 1 4 2 0 3 2 95 2 7 1 4 2 1 3 6 100 2 8 2 2 3 10 105 2 8 3 4 2 2 3 4 4 1 110 2 9 3 4 2 3 1 2 4 4 115 2 10 1 4 2 4 1 4 4 8 120 2 11 2 4 3 4 4 11 Crown Industrial Operators 213 Michelle Ct So San Francisco Ca 94080 6202 Phone 650 952 5150 Fax 650 873 1495 www crown industrial com Email autodor crown industrial com G 993 R3 3 ...

Page 6: ... 1 4 3 7 3 4 105 3 1 3 8 2 5 1 8 3 8 7 8 110 3 2 1 4 2 6 1 8 3 9 3 4 115 3 3 2 6 7 8 3 10 1 2 120 3 3 5 8 2 7 1 2 3 11 1 8 1 8 2 3 8 1 2 1 10 1 5 1 3 14 Crown Industrial Operators 213 Michelle Ct So San Francisco Ca 94080 6202 Phone 650 952 5150 Fax 650 873 1495 www crown industrial com Email autodor crown industrial com G 993 R3 4 ...

Page 7: ... 2 95 2 7 1 4 2 1 3 6 100 2 8 2 2 3 10 105 2 8 3 4 2 2 3 4 4 1 110 2 9 3 4 2 3 1 2 4 4 115 2 10 1 4 2 4 1 4 4 8 120 2 11 2 4 3 4 4 11 Crown Industrial Operators 213 Michelle Ct So San Francisco Ca 94080 6202 Phone 650 952 5150 Fax 650 873 1495 www crown industrial com Email autodor crown industrial com G 993 R3 5 ...

Page 8: ...ed between the crank and connecting arms as the gate reaches the open position 6 When the gate is fully open the arms should assume the position shown by the dotted lines in Figure 3 4 or 5 If the arms reach a locking position before the gate is fully open a re adjustment of the arms is required E WIRING THE OPERATOR 1 Wire the Operator and control circuit as shown onokay the wiring diagram enclos...

Page 9: ...ped by forcing the end of the crank arm and never I just bolts consecutively but always directly across from each other so as to provide even tension An equal turn of each bolt is a very important adjustment procedure WARNING Some electrical gate operator control circuits can cause immediate gate operation upon applying power Ensure that the path of the gate and operating arm is free from obstruct...

Page 10: ...ex extreme pressure grease NLGI No 2 3 For Extra Heavy Duty Units 1 H P check green colored tag attached to the gearmotor CAUTION Do Not Overfill Do Not Use Machine Oil C PREVENTATIVE MAINTENANCE To prevent damage or improper operation the following inspections should be made at least EVERY SIX MONTHS 1 Check pivot points for wear 2 Inspect drive belt for wear Does not apply to Extra Heavy Duty 1 ...

Page 11: ...art 4 Indicate how the material should ship 5 State whether transportation charges are to be prepaid or collect 6 Name and address of person or company to whom invoice is to be sent B PARTS LIST The following pages list the replacement parts illustrated in Figure 8 and 9 Crown Industrial Operators 213 Michelle Ct So San Francisco Ca 94080 6202 Phone 650 952 5150 Fax 650 873 1495 www crown industri...

Page 12: ...Shaft Oil Seal 8 1500 116 Worm 8 1500 117 Arm Plate Cap 8 1500 118 Arm Plate Cap Gasket 8 1500 124 Pinion Shaft Key 8 1500 253 Upper Gear Housing Incl 1500 34 1500 46 Bearing 8 1500 254 Lower Gear Housing Incl 1500 34 1500 45 Bearing 8 1500 255 Release Yoke 8 1500 256 Clutch Bolt 8 1500 257 Bottom Clutch Plate 8 1500 258 Worm Shaft 8 1500 259 Switch Throw Pinion 8 1500 260 Switch Cam 2 per operato...

Page 13: ...of Parts Heavy Duty 1 2 3 4 1 HP Operator Crown Industrial Operators 213 Michelle Ct So San Francisco Ca 94080 6202 Phone 650 952 5150 Fax 650 873 1495 www crown industrial com Email autodor crown industrial com G 993 R3 11 ...

Page 14: ...y Consisting of Parts 64 65 66 69 73 75 77 213 and 405 226 8 1500 227A Top Cover Assembly L H 8 1500 228A Top Cover Assembly R H 8 1500 229A Front Cover L H 8 1500 230A Front Cover R H 8 1500 231 Motor Shim 8 1500 237A Clutch Lever Assembly 8 1500 238 Release Pivot Pin 8 1500 240 Gearmotor 230 460 60 3 R H 8 1500 241 Gearmotor 230 460 60 3 L H 8 1500 259 Switch Throw Pinion 8 1500 260 Switch Cam 2...

Page 15: ...ation of Parts Extra Heavy Duty 1 HP Crown Industrial Operators 213 Michelle Ct So San Francisco Ca 94080 6202 Phone 650 952 5150 Fax 650 873 1495 www crown industrial com Email autodor crown industrial com G 993 R3 13 ...

Page 16: ...SULTING FROM ANY SUCH DEFECTIVE PRODUCT IS STRICTLY LIMITED TO THE DELIVERY OF NEW PARTS AS SET FORTH ABOVE Operator Serial Number _______________________________ H P ____________________________________ Supplied on Crown Industrial Operators Order Number __________________________________________________ Power Supply ____________ Volts ___________ Hz _______________ Phase ________________________...