22
| PT5300
This is the menu for setting the parameters for the analog Black Burst outputs. The analog Black Burst outputs are
named BB1 and BB2 at the connectors on the back of the instrument. These are the outputs from the Black Burst
generator installed as part of the base PT5300 unit.
Setting of the BLACK-BURST generator:
MENU:BLACK-BURST, configure
SUBMNU:<BB1>BB2
• Use the and buttons to select BB1
• Then press
to enter the submenu for BB1
SUBMNU:BLACK-BURST/BB1,select
2NDMNU:<SYSTEM> TIMING SCH-PHASE
The 2NDMNU allows changes to be made in the parameters for the BB1 output.
To change from NTSC to PAL, select SYSTEM
Operation:
2NDMNU:../BB1/SYSTEM, select
SYSTEM:<PAL w/PAL ID> SAVE ESC
• Use the
and
buttons to find the system setting you want.
• When the desired system appears in the display, move the cursor to SAVE and press E to change the
system setting.
• If no change is desired, move the cursor to ESC and press .
Leaving the function takes you back to the BLACK-BURST/BB1 submenu.
Analog Black Burst generator system options:
• NTSC
• PAL
• PAL w/PAL ID
Note:
If the PAL Field 1 pulse in Line 7 is inserted, it is independent of the SCH (SubCarrier to Horizontal) phase
setting. If the SCH phase has been adjusted, the Line 7 pulse will identify the field as if the phase had not been
changed from the nominal setting. When the system
“PAL w/PAL ID” is selected, a pulse indicating PAL Field 1 is
included Line 7.
Note:
When changing the system from PAL to NTSC you must check the timing adjustment: a valid PAL timing may
NOT be valid in NTSC. If the timing is not valid in NTSC then it will be reset to +0,+0,+0.
To change the delay/advance timing for the BB1 output, select TIME.
2NDMNU:../BB1/TIMING, edit delay
V:<+1> H:+008 T: +00124.3 SAVE ESC